Openings shall be provided so that all parts of the incinerator can be cleaned, including the ash pit, the combustion chamber, the passes of separation chambers, and the incinerator flue. Cleanouts shall be closed by tight fitting doors or covers, securely latched or otherwise held in a closed position. Ash pit and combustion chamber closures and frames shall be of cast iron or equivalent, with the frames securely attached to the incinerator.

Related Code Sections

1103.4 Storm Drainage, Cleanout
An accessible cleanout shall be installed on the building side of the trap ...
1103.4 Storm Drainage, Cleanout
An accessible cleanout shall be installed on the building side of the trap ...
1103.4 Storm Drainage, Cleanout
An accessible cleanout shall be installed on the building side of the trap ...
1303.5.3 Nonpotable Water Systems, Cleanouts
Cleanouts shall be provided in accordance with Chapter 11 of this code in the water conveyance system and to allow access to all filters, flushes ...
501.15.3 Chimneys and Vents, Cleanout
Masonry chimney flues shall be provided with a cleanout opening having a minimum height of 6 inches (152.4 mm). The upper edge of the opening shall ...