// CODE SNIPPET
1926.60(j)(3) Cleaning and Replacement
JUMP TO FULL CODE CHAPTER
The employer shall provide the employee with clean protective clothing and equipment. The employer shall ensure that protective work clothing or equipment required by this paragraph is cleaned, laundered, repaired, or replaced at intervals appropriate to maintain its effectiveness.
The employer shall ensure that laundering of MDA-contaminated clothing shall be done so as to prevent the release of MDA in the workplace.
Any employer who gives MDA-contaminated clothing to another person for laundering shall inform such person of the requirement to prevent the release of MDA.
The employer shall inform any person who launders or cleans protective clothing or equipment contaminated with MDA of the potentially harmful effects of exposure.
The employer shall prohibit the removal of MDA from protective work clothing or equipment by blowing, shaking, or any methods which allow MDA to re-enter the workplace.
Related Code Sections
1926.1124(h)(3) Toxic and Hazardous Substances, Cleaning and Replacement
The employer must ensure that all reusable personal protective clothing and equipment required by this standard is cleaned, laundered, repaired ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1124 Beryllium > 1926.1124(h) Personal Protective Clothing and Equipment— > 1926.1124(h)(3) Cleaning and Replacement
1926.1126(g)(3) Toxic and Hazardous Substances, Cleaning and Replacement
The employer shall clean, launder, repair and replace all protective clothing and equipment required by this section as needed to maintain its ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1126 Chromium (VI) > 1926.1126(g) Protective Work Clothing and Equipment > 1926.1126(g)(3) Cleaning and Replacement
1926.60(j)(3) Occupational Health and Environmental Controls, Cleaning and Replacement
or equipment required by this paragraph is cleaned, laundered, repaired, or replaced at intervals appropriate to maintain its effectiveness ...
OSHA 1926 Construction > D Occupational Health and Environmental Controls > 1926.60 Methylenedianiline > 1926.60(j) Protective Work Clothing and Equipment > 1926.60(j)(3) Cleaning and Replacement
1926.62(g)(2) Occupational Health and Environmental Controls, Cleaning and Replacement
The employer shall provide the protective clothing required in paragraph (g)(1) of this section in a clean and dry condition at least weekly ...
OSHA 1926 Construction > D Occupational Health and Environmental Controls > 1926.62 Lead > 1926.62(g) Protective Work Clothing and Equipment > 1926.62(g)(2) Cleaning and Replacement
1926.1127(i)(3) Toxic and Hazardous Substances, Cleaning, Replacement, and Disposal
The employer shall provide the protective clothing and equipment required by paragraph (i)(1) of this section in a clean and dry condition as often ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1127 Cadmium > 1926.1127(i) Protective Work Clothing and Equipment > 1926.1127(i)(3) Cleaning, Replacement, and Disposal