• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2113.12 Clay Flue Lining (Installation)

Building Code 2021 of Illinois > 21 Masonry > 2113 Masonry Chimneys > 2113.12 Clay Flue Lining (Installation)
JUMP TO FULL CODE CHAPTER
Clay flue liners shall be installed in accordance with ASTM C1283 and extend from a point not less than 8 inches (203 mm) below the lowest inlet or, in the case of fireplaces, from the top of the smoke chamber to a point above the enclosing walls. The lining shall be carried up vertically, with a maximum slope not greater than 30 degrees (0.52 rad) from the vertical.
Clay flue liners shall be laid in medium-duty nonwater-soluble refractory mortar conforming to ASTM C199 with tight mortar joints left smooth on the inside and installed to maintain an airspace or insulation not to exceed the thickness of the flue liner separating the flue liners from the interior face of the chimney masonry walls. Flue lining shall be supported on all sides. Only enough mortar shall be placed to make the joint and hold the liners in position.

Related Code Sections


2113.12 Masonry, Clay Flue Lining (Installation)
Clay flue liners shall be installed in accordance with ASTM C1283 and extend from a point not less than 8 inches (203 mm) below the lowest inlet ...
Building Code 2021 of Illinois > 21 Masonry > 2113 Masonry Chimneys > 2113.12 Clay Flue Lining (Installation)
2113.12 Masonry, Clay Flue Lining (Installation)
Clay flue liners shall be installed in accordance with ASTM C1283 and extend from a point not less than 8 inches (203 mm) below the lowest inlet ...
Building Code 2018 of Illinois > 21 Masonry > 2113 Masonry Chimneys > 2113.12 Clay Flue Lining (Installation)
Section 2113 Masonry, Masonry Chimneys
Flue lining systems shall comply with one of the following: Clay flue lining complying with the requirements of ASTM ...
Building Code 2018 of Illinois > 21 Masonry > 2113 Masonry Chimneys
2113.16.2 Masonry, Determination of Minimum Area
the equivalent net cross-sectional area shall be used. Cross-sectional areas of clay flue linings are as provided in Tables 2113.16(1) and 2113.16(2 ...
Building Code 2021 of Illinois > 21 Masonry > 2113 Masonry Chimneys > 2113.16 Flue Area (Masonry Fireplace) > 2113.16.2 Determination of Minimum Area
2113.16.2 Masonry, Determination of Minimum Area
the equivalent net cross-sectional area shall be used. Cross-sectional areas of clay flue linings are as provided in Tables 2113.16(1) and 2113.16(2 ...
Building Code 2018 of Illinois > 21 Masonry > 2113 Masonry Chimneys > 2113.16 Flue Area (Masonry Fireplace) > 2113.16.2 Determination of Minimum Area
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING