• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(b) 803.1.2 Classification in Accordance With NFPA 286 as Listed in Rule 1301:7-7-47 of the Administrative Code

Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 803 Interior Wall and Ceiling Finish and Trim in Existing Buildings > 803.1 General > 803.1.2 Classification in Accordance With NFPA 286 as Listed in Rule 1301:7-7-47 of the Administrative Code
JUMP TO FULL CODE CHAPTER
Interior wall or ceiling finishes shall be allowed to be tested in accordance with NFPA 286 as listed in rule 1301:7-7-47 of the Administrative Code. Finishes tested in accordance with NFPA 286 as listed in rule 1301:7-7-47 of the Administrative Code shall comply with paragraph (C)(1)(b)(i)(803.1.2.1) of this rule. Interior wall and ceiling finish materials tested in accordance with NFPA 286 as listed in rule 1301:7-7-47 of the Administrative Code and meeting the acceptance criteria of paragraph (C)(1)(b)(i)(803.1.2.1) of this rule, shall be allowed to be used where a Class A classification in accordance with ASTM E 84 as listed in rule 1301:7-7-47 of the Administrative Code is required.

(i) 803.1.2.1 Acceptance Criteria for Interior Finish Material Tested to NFPA 286 as Listed in Rule 1301:7-7-47 of the Administrative Code

During the 40 kilowatt (kW) exposure, the interior finish shall comply with paragraph (a) of this rule. During the 160 kW exposure, the interior finish shall comply with paragraph (b) of this rule. During the entire test, the interior finish shall comply with paragraph (c) of this rule.
(a) During the 40 kW exposure, flames shall not spread to the ceiling.
(b) During the 160 kW exposure, the interior finish shall comply with the following:
(i) Flame shall not spread to the outer extremity of the sample on any wall or ceiling.
(ii) Flashover, as defined in NFPA 286 as listed in rule 1301:7-7-47 of the Administrative Code, shall not occur.
(c) The total smoke released throughout the NFPA 286 test as listed in rule 1301:7-7-47 of the Administrative Code shall not exceed 1,000 m2.

Related Code Sections


803.1.2 Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings, Classification in Accordance With NFPA 286 as Listed in Rule 1301:7-7-47 of the Administrative Code
Interior wall or ceiling finishes shall be allowed to be tested in accordance with NFPA 286 as listed in rule 1301:7-7-47 of the Administrative Code ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 803 Interior Wall and Ceiling Finish and Trim in Existing Buildings > 803.1 General > 803.1.2 Classification in Accordance With NFPA 286 as Listed in Rule 1301:7-7-47 of the Administrative Code
803.1.2 Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings, Classification in Accordance With NFPA 286 as Listed in Rule 1301:7-7-80 of the Administrative Code
Code . Finishes tested in accordance with NFPA 286 as listed in rule 1301:7-7-80 of the Administrative Code shall comply with paragraph (C)(1)(b ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 803 Interior Wall and Ceiling Finish and Trim in Existing Buildings > 803.1 General > 803.1.2 Classification in Accordance With NFPA 286 as Listed in Rule 1301:7-7-80 of the Administrative Code
Section 804 Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings, Interior Wall and Ceiling Trim in New and Existing Buildings
material has been tested as an interior finish in accordance with NFPA 286 as listed in rule 1301:7-7-47 of the Administrative Code and complies ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 804 Interior Wall and Ceiling Trim in New and Existing Buildings
606.16 Ohio Administrative Code 1301:7-7-06 Building Services and Systems, Electrical Equipment
Where refrigerants of Groups A2, A3, B2 and B3, as defined in the mechanical code as listed in rule 1301:7-7-47 of the Administrative Code ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-06 Building Services and Systems > 606 Mechanical Refrigeration > 606.16 Electrical Equipment
Section 803 Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings, Interior Wall and Ceiling Finish and Trim in Existing Buildings
, or in accordance with NFPA 286 as listed in rule 1301:7-7-47 of the Administrative Code, as indicated in paragraph (C)(1)(b)(803.1.2) of this rule ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 803 Interior Wall and Ceiling Finish and Trim in Existing Buildings
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING