• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(a) 803.1.1 Classification in Accordance With ASTM E 84 as Listed in Rule 1301:7-7-47 of the Administrative Code

Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 803 Interior Wall and Ceiling Finish and Trim in Existing Buildings > 803.1 General > 803.1.1 Classification in Accordance With ASTM E 84 as Listed in Rule 1301:7-7-47 of the Administrative Code
JUMP TO FULL CODE CHAPTER

Interior finish materials shall be grouped in the following classes in accordance with their flame spread and smoke-developed index when tested in accordance with ASTM E 84 as listed in rule 1301:7-7-47 of the Administrative Code.

(i) Class A: flame spread index 0-25; smoke-developed index 0-450.

(ii) Class B: flame spread index 26-75; smoke-developed index 0-450.

(iii) Class C: flame spread index 76-200; smoke-developed index 0-450.

Related Code Sections


803.1.1 Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings, Classification in Accordance With ASTM E 84 as Listed in Rule 1301:7-7-47 of the Administrative Code
in accordance with ASTM E 84 as listed in rule 1301:7-7-47 of the Administrative Code. (i) Class A: flame spread index 0-25; smoke-developed index 0 ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 803 Interior Wall and Ceiling Finish and Trim in Existing Buildings > 803.1 General > 803.1.1 Classification in Accordance With ASTM E 84 as Listed in Rule 1301:7-7-47 of the Administrative Code
Section 804 Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings, Interior Wall and Ceiling Trim in New and Existing Buildings
indices, when tested in accordance with ASTM E 84 or UL 723 as listed in rule 1301:7-7-47 of the Administrative Code, as described in paragraph (C ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 804 Interior Wall and Ceiling Trim in New and Existing Buildings
804.1.1 Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings, Alternate Testing
for flame spread index and smoke-developed index in accordance with ASTM E 84 as listed in rule 1301:7-7-47 of the Administrative Code ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 804 Interior Wall and Ceiling Trim in New and Existing Buildings > 804.1 Interior Trim > 804.1.1 Alternate Testing
803.9 Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings, Site-Fabricated Stretch Systems
are tested in accordance with ASTM E 84 or UL 723 as listed in rule 1301:7-7-47 of the Administrative Code , specimen preparation and mounting shall ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 803 Interior Wall and Ceiling Finish and Trim in Existing Buildings > 803.9 Site-Fabricated Stretch Systems
804.2 Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings, Foam Plastic
75 where tested in accordance with ASTM E 84 or UL 723 as listed in rule 1301:7-7-47 of the Administrative Code. The smoke-developed index shall ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings > 804 Interior Wall and Ceiling Trim in New and Existing Buildings > 804.2 Foam Plastic
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE