1926.1101(g)(10) Class IV Asbestos Work
JUMP TO FULL CODE CHAPTER
Class IV asbestos jobs shall be conducted by employees trained pursuant to the asbestos awareness training program set out in paragraph (k)(9) of this section. In addition, all Class IV jobs shall be conducted in conformity with the requirements set out in paragraph (g)(1) of this section, mandating wet methods, HEPA vacuums, and prompt clean up of debris containing ACM or PACM.
Employees cleaning up debris and waste in a regulated area where respirators are required shall wear respirators which are selected, used and fitted pursuant to provisions of paragraph (h) of this section.
Employers of employees who clean up waste and debris in, and employers in control of, areas where friable thermal system insulation or surfacing material is accessible, shall assume that such waste and debris contain asbestos.
Related Code Sections
1926.1101(g)(10) Toxic and Hazardous Substances, Class IV Asbestos Work
Class IV asbestos jobs shall be conducted by employees trained pursuant to the asbestos awareness training program set out in paragraph (k)(9 ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(g) Methods of Compliance > 1926.1101(g)(10) Class IV Asbestos Work
1926.1101(h) Toxic and Hazardous Substances, Respiratory Protection
Class IV asbestos work performed within regulated areas where employees who are performing other work ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(h) Respiratory Protection
1926.1101(o)(4) Toxic and Hazardous Substances, Training for the Competent Person
For Class III and IV asbestos work, the competent person shall be trained in aspects of asbestos handling appropriate for the nature ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(o) Competent Person > 1926.1101(o)(4) Training for the Competent Person
1926.1101(o) Toxic and Hazardous Substances, Competent Person
For Class III and IV asbestos work, the competent person shall be trained in aspects ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(o) Competent Person
1926.1101(b) Toxic and Hazardous Substances, Definitions
and maintenance operations, where "ACM", including TSI and surfacing ACM and PACM, is likely to be disturbed.
Class IV asbestos work means maintenance ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(b) Definitions