§28-104.7.6 City Datum
JUMP TO FULL CODE CHAPTER
All elevations noted in the construction documents shall be referred to and clearly identified as the North American vertical datum of 1988 ("NAVD") as established and maintained by National Geodetic Survey of the National Ocean Service, National Oceanic and Atmospheric Administration or successor agency, which is hereby established as the city datum. Neither the United States coast and geodetic survey mean sea level datum of 1929 (national geodetic vertical datum, ("NGVD") nor any of the five borough data as established by the former Board of Estimate and Apportionment shall be referred to in construction documents except as may be required for the purpose of demonstrating conversion to the NAVD. Conversions to NAVD shall be performed by registered design professionals or surveyors. Conversion to and from borough data and NGVD shall be performed using tables 104.7.6.1 through 104.7.6.5.
BRONX ELEVATIONS | TO OBTAIN EQUIVALENCY: | NGVD ELEVATIONS |
10.000 | →add 2.608→ | 12.608 |
7.392 | →add 2.608→ | 10.000 |
BROOKLYN ELEVATIONS | TO OBTAIN EQUIVALENCY: | NGVD ELEVATIONS3 |
10.000 | →add 2.547→ | 12.547 |
7.453 | →add 2.547→ | 10.000 |
MANHATTAN ELEVATIONS | TO OBTAIN EQUIVALENCY: | NGVD ELEVATIONS |
10.000 | →add 2.752→ | 12.752 |
7.248 | →add 2.752→ | 10.000 |
QUEENS ELEVATIONS | TO OBTAIN EQUIVALENCY: | NGVD ELEVATIONS |
10.000 | →add 2.725→ | 12.725 |
7.275 | →add 2.725→ | 10.000 |
STATEN ISLAND ELEVATIONS | TO OBTAIN EQUIVALENCY: | NGVD ELEVATIONS |
10.000 | →add 3.192→ | 13.192 |
6.808 | →add 3.192→ | 10.000 |
Related Code Sections
§28-104.7.6 Administration, City Datum
agency, which is hereby established as the city datum. Neither the United States coast and geodetic survey mean sea level datum of 1929 (national ...
NYC General Admin. Provisions 2008 > 1 Administration > 104 Construction Documents > §28-104.7 Submittal of Construction Documents > §28-104.7.6 City Datum
§28-104.7.6 Administration, City Datum
agency, which is hereby established as the city datum. Neither the United States coast and geodetic survey mean sea level datum of 1929 (national ...
NYC General Admin. Provisions 2014 > 1 Administration > 104 Construction Documents > §28-104.7 Submittal of Construction Documents > §28-104.7.6 City Datum
106.3 Administration, Lot Diagram
diagram shall be drawn in accordance with an accurate boundary survey to the city datum, made by a land surveyor, which shall be attached to and form part ...
107.3 Administration, Lot Diagram
diagram shall be drawn in accordance with an accurate boundary survey to the city datum, made by a land surveyor, which shall be attached to and form part ...
Article 3 Administration [PDF] (page 4)
coast and geodetic survey which is hereby established as the city datum. (2.1.1.3). §C26-163.0 Information as to Subsoil Conditions.-Applications ...