Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1211.2 Chlorinated Polyvinyl Chloride (CPVC) Pipe

Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1211.0 Joints and Connections > 1211.2 Chlorinated Polyvinyl Chloride (CPVC) Pipe
JUMP TO FULL CODE CHAPTER
Joints between chlorinated polyvinyl chloride (CPVC) pipe or fittings shall be installed in accordance with one of the following methods:
  1. Mechanical joints shall include flanged, grooved, and push fit fittings. Removable and non-removable push fit fittings with an elastomeric o-ring that employ quick assembly push fit connectors shall be in accordance with ASSE 1061.
  2. Solvent cement joints for CPVC pipe and fittings shall be clean from dirt and moisture. Solvent cements in accordance with ASTM F493, requiring the use of a primer shall be orange in color. The primer shall be colored and be in accordance with ASTM F656. Listed solvent cement in accordance with ASTM F493 that does not require the use of primers, yellow or red in color, shall be permitted for pipe and fittings manufactured in accordance with ASTM D2846, 1/2 of an inch (15 mm) through 2 inches (50 mm) in diameter or ASTM F442, 1/2 of an inch (15 mm) through 3 inches (80 mm) in diameter. Apply primer where required inside the fitting and to the depth of the fitting on pipe. Apply liberal coat of cement to the outside surface of pipe to depth of fitting and inside of fitting. Place pipe inside fitting to forcefully bottom the pipe in the socket and hold together until joint is set.
  3. Threaded joints for CPVC pipe shall be made with pipe threads in accordance with ASME B1.20.1. A minimum of Schedule 80 shall be permitted to be threaded, and the pressure rating shall be reduced by 50 percent. The use of molded fittings shall not result in a 50 percent reduction in the pressure rating of the pipe provided that the molded fittings shall be fabricated so that the wall thickness of the material is maintained at the threads. Thread sealant compound that is compatible with the pipe and fitting, insoluble in water, and nontoxic shall be applied to male threads. Caution shall be used during assembly to prevent over tightening of the CPVC components once the thread sealant has been applied. Female CPVC threaded fittings shall be used with plastic male threads only.

Related Code Sections


1211.2 Hydronics, Chlorinated Polyvinyl Chloride (CPVC) Pipe
Joints between chlorinated polyvinyl chloride (CPVC) pipe or fittings shall be installed in accordance with one of the following methods ...
Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1211.0 Joints and Connections > 1211.2 Chlorinated Polyvinyl Chloride (CPVC) Pipe
1208.6.5 Fuel Gas Piping, Plastic Pipe, Tubing, and Fittings
D2513." Polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) plastic pipe, tubing, and fittings shall not be used to supply fuel gas ...
Uniform Plumbing Code 2018 of Nevada > 12 Fuel Gas Piping > 1208.0 Gas Piping System Design, Materials, and Components > 1208.6 Acceptable Piping Materials and Joining Methods > 1208.6.5 Plastic Pipe, Tubing, and Fittings
P2906.5 Water Supply and Distribution, Water Distribution Pipe
DISTRIBUTION PIPE MATERIAL STANDARD Chlorinated polyvinyl chloride (CPVC) plastic pipe ...
Residential Code 2018 of Nevada > 29 Water Supply and Distribution > P2906 Materials, Joints and Connections > P2906.5 Water Distribution Pipe
6.3.1.1 System Components and Hardware,
Polyvinyl chloride (CPVC) Pipe ASTM F442 Brass Pipe Specification for Seamless Red Brass Pipe ASTM B43 Stainless Steel ...
Standard for the Installation of Sprinkler Systems 2016 of Nevada > 6 System Components and Hardware > 6.3 Aboveground Pipe and Tube > 6.3.1 General > 6.3.1.1
1308.5.4 Fuel Gas Piping, Plastic Pipe, Tubing, and Fittings
D2513." [NFPA 54:5.6.4.1.1] Polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) plastic pipe, tubing, and fittings shall not be used ...
Uniform Mechanical Code 2018 of Nevada > 13 Fuel Gas Piping > 1308.0 Gas Piping System Design, Materials, and Components > 1308.5 Acceptable Piping Materials and Joining Methods > 1308.5.4 Plastic Pipe, Tubing, and Fittings
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING