• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R1003.20 Chimney Crickets

Residential Code 2018 of Kansas > 10 Chimneys and Fireplaces > R1003 Masonry Chimneys > R1003.20 Chimney Crickets
JUMP TO FULL CODE CHAPTER

Chimneys shall be provided with crickets where the dimension parallel to the ridgeline is greater than 30 inches (762 mm) and does not intersect the ridgeline. The intersection of the cricket and the chimney shall be flashed and counterflashed in the same manner as normal roof-chimney intersections. Crickets shall be constructed in compliance with Figure R1003.20 and Table R1003.20.

TABLE R1003.20

CRICKET DIMENSIONS

ROOF SLOPEH
12:121/2 of W
8:121/3 of W
6:121/4 of W
4:121/6 of W
3:121/8 of W

For SI: 1 inch = 25.4 mm.

FIGURE R1003.20

CHIMNEY CRICKET

Related Code Sections


R1003.20 Chimneys and Fireplaces, Chimney Crickets
Chimneys shall be provided with crickets where the dimension parallel to the ridgeline is greater than 30 inches (762 mm) and does not intersect ...
Residential Code 2018 of Kansas > 10 Chimneys and Fireplaces > R1003 Masonry Chimneys > R1003.20 Chimney Crickets
1503.5 Roof Assemblies and Rooftop Structures, Crickets and Saddles
A cricket or saddle shall be installed on the ridge side of any chimney or penetration greater than 30 inches (762 mm) wide as measured perpendicular ...
Building Code 2018 of Kansas > 15 Roof Assemblies and Rooftop Structures > 1503 Weather Protection > 1503.5 Crickets and Saddles
R903.2.2 Roof Assemblies, Crickets and Saddles
A cricket or saddle shall be installed on the ridge side of any chimney or penetration more than 30 inches (762 mm) wide as measured perpendicular ...
Residential Code 2018 of Kansas > 9 Roof Assemblies > R903 Weather Protection > R903.2 Flashing > R903.2.2 Crickets and Saddles
603.2 Building Services and Systems, Chimneys
Masonry chimneys shall be constructed in accordance with the International Building Code . Factory-built chimneys shall be installed in accordance ...
Fire Code 2018 of Kansas > 6 Building Services and Systems > 603 Fuel-Fired Appliances > 603.2 Chimneys
Chapter 10 Chimneys and Fireplaces
Residential Code 2018 of Kansas > 10 Chimneys and Fireplaces
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE