• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

308.4.2.3 Chimney Connector Pass-Throughs

Mechanical Code 2015 of Utah > 3 General Regulations > 308 Clearance Reduction > 308.4 Allowable Reduction > 308.4.2 Reduction Table > 308.4.2.3 Chimney Connector Pass-Throughs
JUMP TO FULL CODE CHAPTER
The clearance reduction methods specified in Table 308.4.2 shall not be utilized to reduce the clearances required for chimney connector pass-throughs as specified in Section 803.10.4.

Related Code Sections


308.4.2.3 General Regulations, Chimney Connector Pass-Throughs
The clearance reduction methods specified in Table 308.4.2 shall not be utilized to reduce the clearances required for chimney connector pass ...
Mechanical Code 2015 of Utah > 3 General Regulations > 308 Clearance Reduction > 308.4 Allowable Reduction > 308.4.2 Reduction Table > 308.4.2.3 Chimney Connector Pass-Throughs
308.4.2.3 General Regulations, Chimney Connector Pass-Throughs
The clearance reduction methods specified in Table 308.4.2 shall not be utilized to reduce the clearances required for chimney connector pass ...
Mechanical Code 2018 of Utah > 3 General Regulations > 308 Clearance Reduction > 308.4 Allowable Reduction > 308.4.2 Reduction Table > 308.4.2.3 Chimney Connector Pass-Throughs
M1803.3.1 Chimneys and Vents, Floor, Ceiling and Wall Penetrations
A chimney connector or vent connector shall not pass through any floor or ceiling. A chimney connector or vent connector shall not pass through ...
Residential Code 2015 of Utah > 18 Chimneys and Vents > M1803 Chimney and Vent Connectors > M1803.3 Installation > M1803.3.1 Floor, Ceiling and Wall Penetrations
803.10.4 Chimneys and Vents, Connector Pass-Through
Chimney connectors shall not pass through any floor or ceiling, nor through a fire-resistance-rated wall assembly. Chimney connectors for domestic ...
Mechanical Code 2018 of Utah > 8 Chimneys and Vents > 803 Connectors > 803.10 Installation > 803.10.4 Connector Pass-Through
803.10.4 Chimneys and Vents, Connector Pass-Through
Chimney connectors shall not pass through any floor or ceiling, nor through a fire-resistance-rated wall assembly. Chimney connectors for domestic ...
Mechanical Code 2015 of Utah > 8 Chimneys and Vents > 803 Connectors > 803.10 Installation > 803.10.4 Connector Pass-Through
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE