308.5.2 Child Daycare Facility
JUMP TO FULL CODE CHAPTER
A facility that provides supervision and personal care on less than a 24-hour basis for more than five children 21/2 years of age or less shall be classified as Group I-4.
Exception: A child day care facility that provides care for more than five but no more than 100 children 21/2 years or less of age, where the rooms in which the children are cared for are located on a level of exit discharge serving such rooms and each of these child care rooms has an exit door directly to the exterior, shall be classified as Group E.
Related Code Sections
308.5.2 Use and Occupancy Classification, Child Daycare Facility
be classified as Group I-4. Exception: A child day care facility that provides care for more than five but no more than 100 children 2 1 / 2 years ...
Ohio Building Code 2011 > 3 Use and Occupancy Classification > 308 Institutional Group I > 308.5 Group I-4, Day Care Facilities > 308.5.2 Child Daycare Facility
112.3 Ohio Administrative Code 1301:7-7-01 Administration, Fire Safety Inspection Fees
to the application for any license issued by the state fire marshal shall be included in the application fee. 2. Fire safety inspection fees for child daycare ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-01 Administration > 112 State Fire Marshal Permits and Inspection Fees > 112.3 Fire Safety Inspection Fees
1026.2 Means of Egress, Use in a Means of Egress
Exterior exit stairways shall not be used as an element of a required means of egress for Groups I-2, I-4 and child care facilities in E ...
Ohio Building Code 2011 > 10 Means of Egress > 1026 Exterior Exit Ramps and Stairways > 1026.2 Use in a Means of Egress
305.2 Use and Occupancy Classification, Day Care
2 1 / 2 years of age, shall be classified as a Group E occupancy. A child day care facility that provides care for more than five but no more than ...
Ohio Building Code 2011 > 3 Use and Occupancy Classification > 305 Educational Group E > 305.2 Day Care