6.1.4 Chevron Bracing
JUMP TO FULL CODE CHAPTER
The bracing system does not include chevron-, V-, or K-braced bays.
For conforming buildings, the evaluator may consider this condition as mitigated, and no calculations are necessary. Check all elements in the braced frames. For chevron- and V-braced frames, the beam shall be a single element that can carry the gravity loads without the intermediate support of the braces. Check the adequacy of the beam for the seismic forces amplified by Cd/2, but not less than 1.5. Consider the effect of buckling of a leg of chevron-bracing or V-bracing, including the continuity, strength, and bracing of the beams and the ability of the connection to permit buckling of the brace while not destroying the capacity for repeated cycles of loading. If K-bracing is used in buildings over two stories, amplify the seismic forces in the bracing and columns by the factor Cd/2, but not less than 1.5.
Related Code Sections
6.1.4 Seismic Evaluation Procedures for Hospital Buildings, Chevron Bracing
The bracing system does not include chevron-, V-, or K-braced bays. For conforming buildings, the evaluator may consider this condition as mitigated ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 6 Procedures for Braced Frames > 6.1 Concentrically Braced Frames > 6.1.4 Chevron Bracing
6.1.4 Seismic Evaluation Procedures for Hospital Buildings, Chevron Bracing
The bracing system does not include chevron-, V-, or K-braced bays. For conforming buildings, the evaluator may consider this condition as mitigated ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 6 Procedures for Braced Frames > 6.1 Concentrically Braced Frames > 6.1.4 Chevron Bracing
4.5.1 Seismic Evaluation Procedures for Hospital Buildings, Complete Frames
, the beams do not continue across in the plane of the wall. For chevron-braced frame systems, the frame is considered incomplete if the beam in the brace ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 4 Procedures for Moment-Resisting Systems > 4.5 Frames Not Part of the Lateral-Force-Resisting System > 4.5.1 Complete Frames
4.5.1 Seismic Evaluation Procedures for Hospital Buildings, Complete Frames
, the beams do not continue across in the plane of the wall. For chevron-braced frame systems, the frame is considered incomplete if the beam in the brace ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 4 Procedures for Moment-Resisting Systems > 4.5 Frames Not Part of the Lateral-Force-Resisting System > 4.5.1 Complete Frames
Article 6 Seismic Evaluation Procedures for Hospital Buildings, Procedures for Braced Frames
The bracing system does not include chevron-, V-, or K-braced bays. For ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 6 Procedures for Braced Frames