Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.1450(e) Chemical Hygiene Plan -- General

OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1450 Occupational Exposure to Hazardous Chemicals in Laboratories > 1910.1450(e) Chemical Hygiene Plan -- General
JUMP TO FULL CODE CHAPTER
(Appendix A of this section is non-mandatory but provides guidance to assist employers in the development of the Chemical Hygiene Plan).

1910.1450(e)(1)

Where hazardous chemicals as defined by this standard are used in the workplace, the employer shall develop and carry out the provisions of a written Chemical Hygiene Plan which is:

1910.1450(e)(1)(i)

Capable of protecting employees from health hazards associated with hazardous chemicals in that laboratory and

1910.1450(e)(1)(ii)

Capable of keeping exposures below the limits specified in paragraph (c) of this section.

1910.1450(e)(2)

The Chemical Hygiene Plan shall be readily available to employees, employee representatives and, upon request, to the Assistant Secretary.

1910.1450(e)(3)

The Chemical Hygiene Plan shall include each of the following elements and shall indicate specific measures that the employer will take to ensure laboratory employee protection;

1910.1450(e)(3)(i)

Standard operating procedures relevant to safety and health considerations to be followed when laboratory work involves the use of hazardous chemicals;

1910.1450(e)(3)(iii)

A requirement that fume hoods and other protective equipment are functioning properly and specific measures that shall be taken to ensure proper and adequate performance of such equipment;

1910.1450(e)(3)(iv)

Provisions for employee information and training as prescribed in paragraph (f) of this section;

1910.1450(e)(3)(v)

The circumstances under which a particular laboratory operation, procedure or activity shall require prior approval from the employer or the employer's designee before implementation;

1910.1450(e)(3)(vi)

Provisions for medical consultation and medical examinations in accordance with paragraph (g) of this section;

1910.1450(e)(3)(vii)

Designation of personnel responsible for implementation of the Chemical Hygiene Plan including the assignment of a Chemical Hygiene Officer, and, if appropriate, establishment of a Chemical Hygiene Committee; and

1910.1450(e)(3)(viii)

Provisions for additional employee protection for work with particularly hazardous substances. These include "select carcinogens," reproductive toxins and substances which have a high degree of acute toxicity. Specific consideration shall be given to the following provisions which shall be included where appropriate:

1910.1450(e)(3)(viii)(A) Establishment of a Designated Area

1910.1450(e)(3)(viii)(B)

Use of containment devices such as fume hoods or glove boxes;

1910.1450(e)(3)(viii)(C)

Procedures for safe removal of contaminated waste; and

1910.1450(e)(3)(viii)(D) Decontamination Procedures

1910.1450(e)(3)(ii)

Criteria that the employer will use to determine and implement control measures to reduce employee exposure to hazardous chemicals including engineering controls, the use of personal protective equipment and hygiene practices; particular attention shall be given to the selection of control measures for chemicals that are known to be extremely hazardous;

1910.1450(e)(4)

The employer shall review and evaluate the effectiveness of the Chemical Hygiene Plan at least annually and update it as necessary.

Related Code Sections


1910.1450(e) Toxic and Hazardous Substances, Chemical Hygiene Plan -- General
(Appendix A of this section is non-mandatory but provides guidance to assist employers in the development of the Chemical Hygiene Plan ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1450 Occupational Exposure to Hazardous Chemicals in Laboratories > 1910.1450(e) Chemical Hygiene Plan -- General
1910.1450(e)(3)(ii) Toxic and Hazardous Substances,
Criteria that the employer will use to determine and implement control measures to reduce employee exposure to hazardous chemicals including ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1450 Occupational Exposure to Hazardous Chemicals in Laboratories > 1910.1450(e) Chemical Hygiene Plan -- General > 1910.1450(e)(3) > 1910.1450(e)(3)(ii)
1910.1450(e)(1)(i) Toxic and Hazardous Substances,
Capable of protecting employees from health hazards associated with hazardous chemicals in that laboratory and ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1450 Occupational Exposure to Hazardous Chemicals in Laboratories > 1910.1450(e) Chemical Hygiene Plan -- General > 1910.1450(e)(1) > 1910.1450(e)(1)(i)
1910.1450(e)(1)(ii) Toxic and Hazardous Substances,
Capable of keeping exposures below the limits specified in paragraph (c) of this section ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1450 Occupational Exposure to Hazardous Chemicals in Laboratories > 1910.1450(e) Chemical Hygiene Plan -- General > 1910.1450(e)(1) > 1910.1450(e)(1)(ii)
1910.1450(e)(3)(i) Toxic and Hazardous Substances,
chemicals; ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1450 Occupational Exposure to Hazardous Chemicals in Laboratories > 1910.1450(e) Chemical Hygiene Plan -- General > 1910.1450(e)(3) > 1910.1450(e)(3)(i)
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE