A5.106.4.3 Changing Rooms
JUMP TO FULL CODE CHAPTER
TABLE A5.106.4.3
For buildings with over 10 tenant-occupants, provide changing/shower facilities for tenant-occupants only in accordance with Table A5.106.4.3 or document arrangements with nearby changing/shower facilities.
Note: Additional information on recommended bicycle accommodations may be obtained from Sacramento Area Bicycle Advocates.
NUMBER OF TENANT-OCCUPANTS | SHOWER/CHANGING FACILITIES REQUIRED2 | 2-TIER (12" X 15" X 72") PERSONAL EFFECTS LOCKERS1, 2 REQUIRED |
0-10 | 0 | 0 |
11-50 | 1 unisex shower | 2 |
51-100 | 1 unisex shower | 3 |
101-200 | 1 shower stall per gender | 4 |
Over 200 | 1 shower stall per gender for each 200 additional tenant-occupants | One 2-tier locker for each 50 additional tenant-occupants |
- One 2-tier locker serves two people. Lockers shall be lockable with either padlock or combination lock.
- Tenant spaces housing more than 10 tenant-occupants within buildings sharing common toilet facilities need not comply; however, such common shower facilities shall accommodate the total number of tenant-occupants served by the toilets and include a minimum of one unisex shower and two 2-tier lockers.
Related Code Sections
A5.106.4.3 Nonresidential Voluntary Measures, Changing Rooms
For buildings with over 10 tenant-occupants, provide changing/shower facilities for tenant-occupants only in accordance with Table A5.106.4.3 ...
California Green Building Standards Code 2019 > A5 Nonresidential Voluntary Measures > A5.106 Site Development > A5.106.4 Reserved > A5.106.4.3 Changing Rooms
A5.106.4.3 Nonresidential Voluntary Measures, Changing Rooms
For buildings with over 10 tenant-occupants, provide changing/shower facilities for tenant-occupants only in accordance with Table A5.106.4.3 ...
California Green Building Standards Code 2016 > A5 Nonresidential Voluntary Measures > A5.106 Site Development > A5.106.4 Reserved > A5.106.4.3 Changing Rooms
1226.11.6.4 Interior Environment, Staff Clothing Change Area
When provided, a changing room with shower shall be provided for staff to change into work attire ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.11 Alternative Birthing Clinics > 1226.11.6 Support Areas for Staff > 1226.11.6.4 Staff Clothing Change Area
407.1.1 Ventilation Air,
The number of air changes may be reduced to 25
percent of the indicated value in Table 4-A, when the room is unoccupied, if provisions are made ...
California Mechanical Code 2019 > 4 Ventilation Air > 407.0 Ventilation System Details > 407.1 General > 407.1.1
418.3.3 Ventilation Air, Cylinder Change
When not located in the ETO sterilizer equipment room, exhaust during cylinder
change is required by installing a hood that is part of a dedicated ...
California Mechanical Code 2016 > 4 Ventilation Air > 418.0 Design Requirements for Ethylene Oxide (Eto) Sterilization Areas > 418.3 Ventilation Requirements > 418.3.3 Cylinder Change