3307.7.4 Chain Link Fences or Gates
JUMP TO FULL CODE CHAPTER
Where a chain link fence or gate is utilized, the following requirements shall apply:
- The fence or gate shall be made of new materials or, where salvaged, the fence shall be in good condition;
- The fence posts shall be of galvanized steel pipe of a diameter that provides rigidity. Posts shall be suitable for setting in concrete footings, for driving into the ground, or for inserting in precast concrete blocks. Such posts shall be spaced in a manner that maintains the required rigidity to form a safe exterior fence;
- The fence or gate shall be constructed of woven, galvanized steel wire mesh and shall be of sufficient strength and rigidity to prevent access to the site; and
- The fence or gate shall be covered with an opaque sturdy cloth "windscreen" fabric at all locations. Fabric shall be securely attached to the fence or gate in accordance with manufacturer specifications. The fabric and fence shall be maintained in a neat, rigid and taut appearance.
Related Code Sections
3307.7.4 Safeguards During Construction or Demolition, Chain Link Fences or Gates
Where a chain link fence or gate is utilized, the following requirements shall apply: The fence or gate shall be made of new materials or, where ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3307 Protection of Pedestrians > 3307.7 Fences > 3307.7.4 Chain Link Fences or Gates
3109.5.1.5 Special Construction, Chain Link Dimensions
Maximum mesh size for chain link fences shall be a 2 1 / 4 inch square (57 mm square) unless the fence is provided with slats fastened at the top ...
NYC Building Code 2008 > 31 Special Construction > 3109 Swimming Pools, Swimming Pool Enclosures, and Safety Devices > 3109.5 Private Swimming Pools > 3109.5.1 Barrier Height and Clearances > 3109.5.1.5 Chain Link Dimensions
3109.5.1.5 Special Construction, Chain Link Dimensions
Maximum mesh size for chain link fences shall be a 2 1 / 4 inch square (57 mm square) unless the fence is provided with slats fastened at the top ...
NYC Building Code 2014 > 31 Special Construction > 3109 Swimming Pools, Swimming Pool Enclosures, and Safety Devices > 3109.5 Private Swimming Pools > 3109.5.1 Barrier Height and Clearances > 3109.5.1.5 Chain Link Dimensions
1008.2 Means of Egress, Gates
Gates serving the means of egress system shall comply with the requirements of this section. Gates used as a component in a means of egress shall ...
1008.2 Means of Egress, Gates
Gates serving the means of egress system shall comply with the requirements of this section. Gates used as a component in a means of egress shall ...