• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5104.3.2.1 Chain-Link Fence Enclosures

Fire Code 2018 of Wyoming > 51 Aerosols > 5104 Inside Storage of Aerosol Products > 5104.3 Storage in General Purpose Warehouses > 5104.3.2 Segregated Storage > 5104.3.2.1 Chain-Link Fence Enclosures
JUMP TO FULL CODE CHAPTER

Chain-link fence enclosures required by Table 5104.3.2 shall comply with the following:

  1. The fence shall be not less than No. 9 gage steel wire, woven into a maximum 2-inch (51 mm) diamond mesh.
  2. The fence shall be installed from the floor to the underside of the roof or ceiling above.
  3. Class IV and high-hazard commodities shall be stored outside of the aerosol storage area and not less than 8 feet (2438 mm) from the fence.
  4. Access openings in the fence shall be provided with either self- or automatic-closing devices or a labyrinth opening arrangement preventing aerosol containers from rocketing through the access openings.
  5. Not less than two means of egress shall be provided from the fenced enclosure.

Related Code Sections


5104.3.2.1 Aerosols, Chain-Link Fence Enclosures
Chain-link fence enclosures required by Table 5104.3.2 shall comply with the following: The fence shall be not less than No. 9 gage steel wire ...
Fire Code 2018 of Wyoming > 51 Aerosols > 5104 Inside Storage of Aerosol Products > 5104.3 Storage in General Purpose Warehouses > 5104.3.2 Segregated Storage > 5104.3.2.1 Chain-Link Fence Enclosures
5104.3.2.1 Aerosols, Chain-Link Fence Enclosures
Chain-link fence enclosures required by Table 5104.3.2 shall comply with the following: The fence shall not be less than No. 9 gage steel wire ...
Fire Code 2015 of Wyoming > 51 Aerosols > 5104 Inside Storage of Aerosol Products > 5104.3 Storage in General Purpose Warehouses > 5104.3.2 Segregated Storage > 5104.3.2.1 Chain-Link Fence Enclosures
Section 5104 Aerosols, Inside Storage of Aerosol Products
, c Chain-link fence enclosure d 20 20,000 Notes b, c 1-hour fire-resistance-rated interior walls 20 30,000 Note b 2-hour fire ...
Fire Code 2018 of Wyoming > 51 Aerosols > 5104 Inside Storage of Aerosol Products
1510.8.4 Roof Assemblies and Rooftop Structures, Fences
Fences and similar structures shall comply with Section 1510.6 as mechanical equipment screens ...
Building Code 2015 of Wyoming > 15 Roof Assemblies and Rooftop Structures > 1510 Rooftop Structures > 1510.8 Other Rooftop Structures > 1510.8.4 Fences
1510.8.4 Roof Assemblies and Rooftop Structures, Fences
Fences and similar structures shall comply with Section 1510.6 as mechanical equipment screens ...
Building Code 2018 of Wyoming > 15 Roof Assemblies and Rooftop Structures > 1510 Rooftop Structures > 1510.8 Other Rooftop Structures > 1510.8.4 Fences
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE