Article 5 Certification of Construction
Go To Full Code ChapterSee More
4-330 Time of Beginning Construction and Partial Construction
Construction work, whether for a new school building, reconstruction, rehabilitation, alteration or addition, shall not be commenced, and no contract shall be let until the school board has applied for and obtained from DSA written approval of plans and specifications. Construction for each school building shall be commenced within four years after the approval of the plans; otherwise, the approval is void for those school buildings that have not commenced construction.
Exception: DSA may withdraw approval or institute postapproval requirements as necessary to address life safety concerns due to information received after approval of plans and before commencement of construction.
The school board may complete all work or proceed with the construction of any part of the work included in the approved plans and specifications with the intent of completing the work later. All work done and materials used and installed must be in accordance with and in conformity to the approved plans and specifications.
An uncompleted building shall not be considered as having been constructed under the provisions of Article 3 or 7 commencing with Sections 17280 and 81130 of the Education Code, respectively. Section 17372 of the Education Code restricts the use of such a building.
Authority: Education Code Sections 17310 and 81142.
Reference: Education Code Sections 17280, 17297, 17307, 17372 and 81130.
4-331 Notice to DSA at Start of Construction
The architect or registered engineer responsible for the project or the school district shall promptly notify DSA of the start of construction using forms and procedures specified by DSA.
Authority: Education Code Sections 17310 and 81142.
Reference: Education Code Sections 17280, 17295, 81130 and 81133.
- (OSA/SS 1/92) Regular order by the Office of the State Architect/Structural Safety Section to amend Section 4-331, Part 1, Title 24, C.C.R. Filed with the Secretary of State on December 15, 1992; effective July 1, 1993. Approved by the California Building Standards Commission on December 9, 1992.
4-332 Notice of Suspension of Construction
- When construction is suspended for more than one month, the project inspector shall notify DSA [see Section 4-336(c)3].
- If all construction is suspended or abandoned for any reason for a continuous period of one year following its commencement, the approval of DSA shall become void. DSA may reinstate the approval on the request of the school board.
Authority: Education Code Sections 17310 and 81142.
Reference: Education Code Sections 17310 and 81142.
- (OSA/SS 1/92) Regular order by the Office of the State Architect/Structural Safety Section to amend Section 4-332, Part 1, Title 24, C.C.R. Filed with the Secretary of State on December 15, 1992; effective July 1, 1993. Approved by the California Building Standards Commission on December 9, 1992.
4-333 Observation and Inspection of Construction
- Observation by architect or registered engineer. The Act requires that the observation of the work of construction, reconstruction, rehabilitation, alteration or addition shall be under the general responsible charge of an architect, structural engineer, or under certain conditions a professional engineer registered in that branch of engineering applicable to the work. (See Section 4-316.)The responsible geotechnical engineer, or his or her qualified representative, shall perform all testing and special inspection of all earth materials, the placement and compaction of engineered fills, and the geotechnical aspects of foundations, retaining walls and foundation anchors. The responsible geotechnical engineer shall submit verified reports in accordance with Section 4-336 and Title 24, Part 2, Section 1704A.7.1.
- Inspection by a project inspector. The school board must provide for and require competent, adequate and continuous inspection by an inspector satisfactory to the architect or registered engineer in general responsible charge of observation of the work of construction; to any registered structural engineer delegated responsibility for a portion of the work; and to DSA.
- The cost of project inspection shall be paid for by the school board. An inspector shall not have any current employment relationship with any entity that is a contracting party for the construction or any entity providing any services for the school district except for services directly related to project inspection.
- Project inspectors are prohibited from any activities involving the actual performance of construction, or the scheduling, coordination or supervision of construction contractors for the project.
- For every project there shall be a project inspector who shall have personal knowledge as defined in Sections 17309 and 81141 of the Education Code of all work done on the project or its parts as defined in Section 4-316. No work shall be carried on except under the inspection of an inspector approved by DSA. On large projects adequate inspection may require the employment of one or more approved assistant inspectors in accordance with Section 4-333(d). The employment of special inspectors or assistant inspectors shall not be construed as relieving the project inspector of his or her duties and responsibilities under Sections 17309 and 81141 of the Education Code and Sections 4-336 and 4-342 of these regulations.
- The project inspector shall be capable of performing all essential functions of the job.
- The project inspector and any assistant inspector must be approved by DSA for each individual project. Prior to being eligible for approval, any project inspector or any assistant inspector shall establish, to the satisfaction of DSA that he or she:
- is appropriately certified by DSA, per Section 4-333.1; and
- has adequate knowledge and experience to perform the required duties for the project. He or she shall have at least three years experience in inspection or construction work on building projects of a type similar to the project. For newly certified inspectors without prior DSA project inspection experience, attendance of DSA-specified training is required; and
- will provide sufficient time on the project to fulfill all inspection responsibilities required by these regulations.
- An approved project inspector may be replaced in accordance with the process outlined in Section 4-341(d). The school district shall ensure that a replacement inspector is provided prior to continuation of construction work. DSA may withhold approval of the replacement inspector until a verified report by the previous project inspector is submitted in accordance with Section 4-336(c)5.
- DSA may withdraw the inspector's approval for the project due to failure of project inspector to comply with the requirements contained in Section 4-342(b). DSA shall communicate the withdrawal of the project inspector's approval in writing to the school district and the architect or registered engineer in general responsible charge. The school district shall ensure that a replacement inspector is provided prior to continuation of construction work.
- The project inspector may perform special inspections if the project inspector has been specially approved by DSA for such purpose and has the time available to complete the special inspections in addition to project inspection work.
- The detailed inspection of all work, as specified in Section 4-335(f), is the responsibility of the project inspector when a special inspector is not provided.
- Special inspection. Special inspection by qualified inspectors shall be in accordance with Title 24, Part 2, Chapter 17A.DSA may require special inspectors for types of construction in addition to those listed in Chapter 17A, Title 24, Part 2 if found necessary because of the special use of materials or methods of construction.
- Assistant inspectors. Assistant inspectors are approved by DSA to assist the project inspector with the inspection of one or more aspects of the construction. Assistant inspectors must work under the supervision of a Class 1 or 2 certified project inspector.
- On large projects DSA may require the employment of assistant inspectors when the project inspector is not able to provide continuous inspection of all aspects of the construction in a timely manner. When assistant inspectors are required by DSA the project inspector shall remain on-site providing supervision of all assistants during all construction.
- All assistant inspectors must be approved by DSA prior to performing any inspection work in accordance with Section 4-341(d). Prior to being approved by DSA as an assistant inspector the individual must satisfy all of the following requirements:
- Be certified as a Class 1, Class 2, Class 3 or Class 4 inspector in accordance with Section 4-333.1.
- Must possess adequate experience for the type of construction that the assistant will be assigned to inspect.
- Document at least three years of experience in the types of construction that the assistant will inspect. Experience must be obtained in construction or inspection of buildings similar to the buildings for which the individual is applying.
- The assistant inspector shall establish, to the satisfaction of DSA that he or she meets all of the requirements established in Section 4-333(b)5.
- Failure of the assistant inspector to perform any of the duties specified in these regulations may be cause for DSA to take action as outlined in Section 4-342(d).
Authority: Education Code Sections 17310 and 81142.
Reference: Education Code Sections 17280, 17309, 17311, 81130, 81138, 81141 and 81143.
- (OSA/SS 1/92) Regular order by the Office of the State Architect/Structural Safety Section to amend Section 4-333, Part 1, Title 24, C.C.R. Filed with the Secretary of State on December 15, 1992; effective July 1, 1993. Approved by the California Building Standards Commission on December 9, 1992.
- (DSA/SS 2/95) Regular order by the Division of the State Architect/Structural Safety Section to amend Section 4-333. Filed with the Secretary of State on August 14, 1996, becomes effective September 13, 1996. Approved by the California Building Standards Commission on March 19, 1996.
Upcodes Diagrams
Related Code Sections
Article 5 Administrative Regulations for the Division of the State Architect—Structural Safety (DSA-SS), Certification of Construction
inspector; or a special inspector (inspecting steel, concrete or masonry construction with a valid certification from a state or nationally-recognized ...
Article 5 Administrative Regulations for the Division of the State Architect—Structural Safety (DSA-SS), Certification of Construction
as: an assistant project inspector; or a special inspector (inspecting steel, concrete or masonry construction with a valid certification from a state ...
Article 5 Safety of Construction of Public Schools, Certification of Construction
, owner's, or local building official's representative in building code-enforcement inspection of non-residential construction with a valid certification ...
Article 5 Safety of Construction of Public Schools: Fire and Life Safety, Certification of Construction
Certification of construction shall be in accordance Chapter 4, Group 1, Article 5 as follows: (a) Time of beginning construction and partial ...
4-328 Administrative Regulations for the Division of the State Architect—Structural Safety (DSA-SS), Fees for DSA Certification of Construction
A fee may be charged to the school district for the review and processing of all required documents submitted for the issuance of certification ...