REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

10-113 Certification and Labeling of Roofing Product Reflectance and Emittance

California Administrative Code 2016 > 10 Administrative Regulations for the California Energy Commission (CEC) > 1 Energy Building Regulations > 10-113 Certification and Labeling of Roofing Product Reflectance and Emittance
JUMP TO FULL CODE CHAPTER

This section establishes rules for implementing labeling and certification requirements relating to reflectance and emittance for roofing products for showing compliance with Sections 140.1, 140.2, 140.3(a)1, 141.0(b)2B, 150.1(c)11, 150.2(b)1H, and 150.2(b)2 of Title 24, California Code of Regulations, Part 6. This section also provides for designation of the Cool Roof Rating Council (CRRC) as the supervisory entity responsible for administering the state's certification program for roofing products, provided CRRC meets specified criteria.

(a) Labeling requirements. Every roofing product installed in construction to take compliance credit or meet the Prescriptive requirements for reflectance and emittance under Sections 140.1, 140.2, 140.3(a)1, 141.0(b)2B, 150.1(c)11, 150.2(b)1H or 150.2(b)2 shall have a clearly visible packaging label that lists the emittance and the initial and 3-year aged solar reflectance, or a CRRC approved accelerated aged solar reflectance, tested in accordance with CRRC-1.

Packaging for liquid-applied roof coatings shall state the product meets the requirements specified in Section 110.8(i)4.

(b) Certification requirements. Every roofing product installed in construction to take compliance credit or meet the Prescriptive requirements for reflectance and emittance under Sections 140.1, 140.2, 140.3(a)1, 141.0(b)2B, 150.1(c)11, 150.2(b)1H or 150.2(b)2 shall be certified by CRRC or another supervisory entity approved by the Commission pursuant to Section 10-113(c).

(c) Designation of supervisory entity. The CRRC shall be the supervisory entity to administer the certification program relating to reflectance and emittance ratings for roofing products, provided the Commission determines that the CRRC meets the criteria in Section 10-113(d).

  1. The Commission may consider designating a supervisory entity other than CRRC if the Commission determines that the CRRC is not meeting the criteria in Section 10-113(d). Such other supervisory entity shall meet the criteria in Section 10-113(d) prior to being designated.
  2. The Commission shall periodically review, at least annually, the structure and operations of the supervisory entity to ensure continuing compliance with the criteria in Section 10-113(d). The supervisory entity shall provide an annual report to the Commission explaining all of the measures it has taken to comply with the criteria in Section 10-113(d).

(d) Criteria for supervisory entity.

  1. Membership in the entity shall be open on a nondiscriminatory basis to any person or organization that has an interest in uniform performance ratings for roofing products, including, but not limited to, members of the roofing industry, building industry, design professionals, specifiers, utilities, government agencies and public interest organizations. The membership shall be composed of a broad cross section of those interested in uniform thermal performance ratings for roofing products.
  2. The governing body of the entity shall reflect a reasonable cross section of the interests represented by the membership.
  3. The entity shall maintain a program of oversight of product manufacturers, laboratories and independent certifying organizations that ensures uniform application of the CRRC testing and rating procedures, labeling and certification, and such other rating procedures for other factors that improves the accuracy of properties of roofing products affecting energy performance as the CRRC and the Commission may adopt.
  4. The entity shall require manufacturers and independent certifying organizations within its program to use only laboratories accredited by the supervisory entity to perform tests under the CRRC rating procedure.
  5. The entity shall maintain appropriate guidelines for testing laboratories and manufacturers, including requirements for adequate:

    1. Possession and calibration of equipment;
    2. Education, competence, and training of personnel;
    3. Quality control;
    4. Record keeping and reporting;
    5. Periodic review including, but not limited to, blind testing by laboratories; inspections of products; and inspections of laboratories, and manufacturing facilities;
    6. Challenges to certified ratings; and
    7. Guidelines to maintain the integrity of the program, including, but not limited to, provisions to avoid conflicts of interest within the rating and certification process.
  6. The entity shall be a nonprofit organization and shall maintain reasonable, nondiscriminatory fee schedules for the services it provides, and shall make its fee schedules, the financial information on which fees are based, and financial statements available to its members for inspection.
  7. The entity shall provide hearing processes that give laboratories, manufacturers and certifying agencies a fair review of decisions that adversely affect them.
  8. The entity shall maintain a certification policy committee whose procedures are designed to avoid conflicts of interest in deciding appeals, resolving disputes and setting policy for the certifying organizations in its program.
  9. The entity shall publish at least annually a directory of products certified and decertified within its program.
  10. The entity itself shall be free from conflict-of-interest ties or to undue influence from any particular roofing product manufacturing interest(s), testing or independent certifying organization(s).
  11. The entity shall provide or authorize the use of labels that can be used to meet the requirements for showing compliance with the requirements of Sections 140.1, 140.2, 140.3(a)1, 141.0(b)2B, 150.1(c)11, 150.2(b)1H and 150.2(b)2, and this section.
  12. The entity's certification program shall allow for multiple participants in each aspect of the program to provide for competition between manufacturers and between testing labs.

Authority: Section 25402.1, Public Resources Code.

Reference: Section 25402.1, Public Resources Code.

Related Code Sections


10-113 Administrative Regulations for the California Energy Commission (CEC), Certification and Labeling of Roofing Product Reflectance and Emittance
This section establishes rules for implementing labeling and certification requirements relating to reflectance and emittance for roofing products ...
California Administrative Code 2016 > 10 Administrative Regulations for the California Energy Commission (CEC) > 1 Energy Building Regulations > 10-113 Certification and Labeling of Roofing Product Reflectance and Emittance
10-113 Administrative Regulations for the California Energy Commission (CEC), Rating and Labeling of Roofing Product Reflectance and Emittance
This section establishes rules for implementing labeling and rating requirements relating to reflectance and emittance for roofing products ...
California Administrative Code 2019 > 10 Administrative Regulations for the California Energy Commission (CEC) > 1 Energy Building Regulations > 10-113 Rating and Labeling of Roofing Product Reflectance and Emittance
A4.106.5.1 Residential Voluntary Measures, Solar Reflectance
TABLE A4.106.5.1(2) TIER 2 — LOW-RISE RESIDENTIAL ROOF SLOPE CLIMATE ZONE MINIMUM 3-YEAR AGED SOLAR REFLECTANCE THERMAL EMITTANCE ...
California Green Building Standards Code 2016 > A4 Residential Voluntary Measures > A4.106 Site Development > A4.106.5 Cool Roof for Reduction of Heat Island Effect > A4.106.5.1 Solar Reflectance
A4.106.5.1 Residential Voluntary Measures, Solar Reflectance
A4.106.5.1(1) TIER 1 — LOW-RISE RESIDENTIAL ROOF SLOPE CLIMATE ZONE MINIMUM 3-YEAR AGED SOLAR REFLECTANCE THERMAL EMITTANCE SRI ≤ 2:12 ...
California Green Building Standards Code 2019 > A4 Residential Voluntary Measures > A4.106 Site Development > A4.106.5 Cool Roof for Reduction of Heat Island Effect > A4.106.5.1 Solar Reflectance
A5.205.3.9.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4],
thermal emittance and 3-year aged solar reflectance shall be certified and labeled according to the requirements of Section 10-113 of Title 24, Part 1 ...
California Green Building Standards Code 2019 > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.205 [OSHPD 1 & 4] Building Envelope > A5.205.3 Insulation and Roofing Products > A5.205.3.9 Roofing Products Solar Reflectance and Thermal Emittance > A5.205.3.9.1
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE