N1101.14 (R401.3) Certificate (Mandatory)
JUMP TO FULL CODE CHAPTER
A permanent certificate shall be completed by the builder or other approved party and posted on a wall in the space where the furnace is located, a utility room or an approved location inside the building. Where located on an electrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. The certificate shall indicate the predominant R-values of insulation installed in or on ceilings, roofs, walls, foundation components such as slabs, basement walls, crawl space walls and floors, and ducts outside conditioned spaces; U-factors of fenestration and the solar heat gain coefficient (SHGC) of fenestration, and the results from any required duct system and building envelope air leakage testing performed on the building. Where there is more than one value for each component, the certificate shall indicate the value covering the largest area. The certificate shall indicate the types and efficiencies of heating, cooling and service water heating equipment. Where a gas-fired unvented room heater, electric furnace, or baseboard electric heater is installed in the residence, the certificate shall indicate "gas-fired unvented room heater," "electric furnace" or "baseboard electric heater," as appropriate. An efficiency shall not be indicated for gas-fired unvented room heaters, electric furnaces and electric baseboard heaters.
Related Code Sections
N1101.14 [RE] Energy Efficiency, (R401.3) Certificate (Mandatory)
A permanent certificate shall be completed by the builder or other approved party and posted on a wall in the space where the furnace is located ...
Residential Code 2018 of Kansas > 11 [RE] Energy Efficiency > N1101 General > N1101.14 (R401.3) Certificate (Mandatory)
R401.3 [RE] Residential Energy Efficiency, Certificate (Mandatory)
A permanent certificate shall be completed by the builder or other approved party and posted on a wall in the space where the furnace is located ...
Energy Conservation Code 2018 of Kansas > 4 [RE] Residential Energy Efficiency > R401 General > R401.3 Certificate (Mandatory)
R401.3 Foundations, Drainage
Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection that does not create a hazard. Lots shall ...
C405.6 [CE] Commercial Energy Efficiency, Electrical Transformers (Mandatory)
in accordance with the test procedure listed in DOE 10 CFR 431. The efficiency shall be verified through certification under an approved certification program ...
Energy Conservation Code 2018 of Kansas > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.6 Electrical Transformers (Mandatory)
(A) Introduction, Mandatory Rules
Mandatory rules of this Code are those that identify actions that are specifically required or prohibited and are characterized by the use ...
National Electrical Code 2017 of Kansas > Introduction > 90 Introduction > 90.5 Mandatory Rules, Permissive Rules, and Explanatory Material > (A) Mandatory Rules