• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.120(p) Certain Operations Conducted Under the Resource Conservation and Recovery Act of 1976 (RCRA)

OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(p) Certain Operations Conducted Under the Resource Conservation and Recovery Act of 1976 (RCRA)
JUMP TO FULL CODE CHAPTER
Employers conducting operations at treatment, storage and disposal (TSD) facilities specified in paragraph (a)(1)(iv) of this section shall provide and implement the programs specified in this paragraph. See the "Notes and Exceptions" to paragraph (a)(2)(iii) of this section for employers not covered.

1910.120(p)(1) Safety and Health Program

The employer shall develop and implement a written safety and health program for employees involved in hazardous waste operations that shall be available for inspection by employees, their representatives and OSHA personnel. The program shall be designed to identify, evaluate and control safety and health hazards in their facilities for the purpose of employee protection, to provide for emergency response meeting the requirements of paragraph (p)(8) of this section and to address as appropriate site analysis, engineering controls, maximum exposure limits, hazardous waste handling procedures and uses of new technologies.

1910.120(p)(2) Hazard Communication Program

The employer shall implement a hazard communication program meeting the requirements of 29 CFR 1910.1200 as part of the employer's safety and program.

NOTE TO §1910.120 - The exemption for hazardous waste provided in 1910.1200 is applicable to this section.

1910.120(p)(3) Medical Surveillance Program

The employer shall develop and implement a medical surveillance program meeting the requirements of paragraph (f) of this section.

1910.120(p)(4) Decontamination Program

The employer shall develop and implement a decontamination procedure meeting the requirements of paragraph (k) of this section.

1910.120(p)(5) New Technology Program

The employer shall develop and implement procedures meeting the requirements of paragraph (o) of this section for introducing new and innovative equipment into the workplace.

1910.120(p)(6) Material Handling Program

Where employees will be handling drums or containers, the employer shall develop and implement procedures meeting the requirements of paragraphs (j)(1)(ii) through (viii) and (xi) of this section, as well as (j)(3) and (j)(8) of this section prior to starting such work.

1910.120(p)(7) Training Program

1910.120(p)(7)(i) New Employees

The employer shall develop and implement a training program which is part of the employer's safety and health program, for employees exposed to health hazards or hazardous substances at TSD operations to enable the employees to perform their assigned duties and functions in a safe and healthful manner so as not to endanger themselves or other employees. The initial training shall be for 24 hours and refresher training shall be for eight hours annually. Employees who have received the initial training required by this paragraph shall be given a written certificate attesting that they have successfully completed the necessary training.

1910.120(p)(7)(iii) Trainers

Trainers who teach initial training shall have satisfactorily completed a training course for teaching the subjects they are expected to teach or they shall have the academic credentials and instruction experience necessary to demonstrate a good command of the subject matter of the courses and competent instructional skills.

1910.120(p)(7)(ii) Current Employees

Employers who can show by an employee's previous work experience and/or training that the employee has had training equivalent to the initial training required by this paragraph, shall be considered as meeting the initial training requirements of this paragraph as to that employee. Equivalent training includes the training that existing employees might have already received from actual site work experience. Current employees shall receive eight hours of refresher training annually.

1910.120(p)(8) Emergency Response Program

1910.120(p)(8)(i) Emergency Response Plan

An emergency response plan shall be developed and implemented by all employers. Such plans need not duplicate any of the subjects fully addressed in the employer's contingency planning required by permits, such as those issued by the U.S. Environmental Protection Agency, provided that the contingency plan is made part of the emergency response plan. The emergency response plan shall be a written portion of the employer's safety and health program required in paragraph (p)(1) of this section. Employers who will evacuate their employees from the worksite location when an emergency occurs and who do not permit any of their employees to assist in handling the emergency are exempt from the requirements of paragraph (p)(8) if they provide an emergency action plan complying with 29 CFR 1910.38.

1910.120(p)(8)(iii) Training

1910.120(p)(8)(iii)(A)

Training for emergency response employees shall be completed before they are called upon to perform in real emergencies. Such training shall include the elements of the emergency response plan, standard operating procedures the employer has established for the job, the personal protective equipment to be worn and procedures for handling emergency incidents.

Exception #1: an employer need not train all employees to the degree specified if the employer divides the work force in a manner such that a sufficient number of employees who have responsibility to control emergencies have the training specified, and all other employees, who may first respond to an emergency incident, have sufficient awareness training to recognize that an emergency response situation exists and that they are instructed in that case to summon the fully trained employees and not attempt control activities for which they are not trained.

Exception #2: An employer need not train all employees to the degree specified if arrangements have been made in advance for an outside fully-trained emergency response team to respond in a reasonable period and all employees, who may come to the incident first, have sufficient awareness training to recognize that an emergency response situation exists and they have been instructed to call the designated outside fully-trained emergency response team for assistance.

1910.120(p)(8)(iii)(B)

Employee members of TSD facility emergency response organizations shall be trained to a level of competence in the recognition of health and safety hazards to protect themselves and other employees. This would include training in the methods used to minimize the risk from safety and health hazards; in the safe use of control equipment; in the selection and use of appropriate personal protective equipment; in the safe operating procedures to be used at the incident scene; in the techniques of coordination with other employees to minimize risks; in the appropriate response to over exposure from health hazards or injury to themselves and other employees; and in the recognition of subsequent symptoms which may result from over exposures.

1910.120(p)(8)(iii)(C)

The employer shall certify that each covered employee has attended and successfully completed the training required in paragraph (p)(8)(iii) of this section, or shall certify the employee's competency for certification of training shall be recorded and maintained by the employer.

1910.120(p)(8)(iv) Procedures for Handling Emergency Incidents

1910.120(p)(8)(iv)(A)

In addition to the elements for the emergency response plan required in paragraph (p)(8)(ii) of this section, the following elements shall be included for emergency response plans to the extent that they do not repeat any information already contained in the emergency response plan:

1910.120(p)(8)(iv)(A)(1)

Site topography, layout, and prevailing weather conditions.

1910.120(p)(8)(iv)(A)(2)

Procedures for reporting incidents to local, state, and federal governmental agencies.

1910.120(p)(8)(iv)(B)

The emergency response plan shall be compatible and integrated with the disaster, fire and/or emergency response plans of local, state, and federal agencies.

1910.120(p)(8)(iv)(C)

The emergency response plan shall be rehearsed regularly as part of the overall training program for site operations.

1910.120(p)(8)(iv)(D)

The site emergency response plan shall be reviewed periodically and, as necessary, be amended to keep it current with new or changing site conditions or information.

1910.120(p)(8)(iv)(E)

An employee alarm system shall be installed in accordance with 29 CFR 1910.165 to notify employees of an emergency situation, to stop work activities if necessary, to lower background noise in order to speed communication; and to begin emergency procedures.

1910.120(p)(8)(iv)(F)

Based upon the information available at time of the emergency, the employer shall evaluate the incident and the site response capabilities and proceed with the appropriate steps to implement the site emergency response plan.

1910.120(p)(8)(ii)

Elements of an emergency response plan. The employer shall develop an emergency response plan for emergencies which shall address, as a minimum, the following areas to the extent that they are not addressed in any specific program required in this paragraph:

1910.120(p)(8)(ii)(A)

Pre-emergency planning and coordination with outside parties.

1910.120(p)(8)(ii)(B)

Personnel roles, lines of authority, training, and communication.

1910.120(p)(8)(ii)(C)

Emergency recognition and prevention.

1910.120(p)(8)(ii)(D)

Safe distances and places of refuge.

1910.120(p)(8)(ii)(E)

Site security and control.

1910.120(p)(8)(ii)(F)

Evacuation routes and procedures.

1910.120(p)(8)(ii)(G)

Decontamination procedures.

1910.120(p)(8)(ii)(H)

Emergency medical treatment and first aid.

1910.120(p)(8)(ii)(I)

Emergency alerting and response procedures.

1910.120(p)(8)(ii)(J)

Critique of response and follow-up.

1910.120(p)(8)(ii)(K)

PPE and emergency equipment.

Related Code Sections


1910.120(p) Hazardous Materials, Certain Operations Conducted Under the Resource Conservation and Recovery Act of 1976 (RCRA)
Employers conducting operations at treatment, storage and disposal (TSD) facilities specified in paragraph (a)(1)(iv) of this section shall provide ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(p) Certain Operations Conducted Under the Resource Conservation and Recovery Act of 1976 (RCRA)
1910.120(p)(6) Hazardous Materials, Material Handling Program
Where employees will be handling drums or containers, the employer shall develop and implement procedures meeting the requirements of paragraphs (j)(1 ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(p) Certain Operations Conducted Under the Resource Conservation and Recovery Act of 1976 (RCRA) > 1910.120(p)(6) Material Handling Program
1910.120(p)(7) Hazardous Materials, Training Program
to health hazards or hazardous substances at TSD operations to enable the employees to perform their assigned duties and functions in a safe and healthful ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(p) Certain Operations Conducted Under the Resource Conservation and Recovery Act of 1976 (RCRA) > 1910.120(p)(7) Training Program
1910.120(p)(8) Hazardous Materials, Emergency Response Program
, standard operating procedures the employer has established for the job, the personal protective equipment to be worn and procedures for handling emergency ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(p) Certain Operations Conducted Under the Resource Conservation and Recovery Act of 1976 (RCRA) > 1910.120(p)(8) Emergency Response Program
1910.120(p)(7)(i) Hazardous Materials, New Employees
to health hazards or hazardous substances at TSD operations to enable the employees to perform their assigned duties and functions in a safe and healthful ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(p) Certain Operations Conducted Under the Resource Conservation and Recovery Act of 1976 (RCRA) > 1910.120(p)(7) Training Program > 1910.120(p)(7)(i) New Employees
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE