• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1917.1.2 Cellular Lightweight Insulating Concrete

2020 FBC - Building, 7th edition > 19 Concrete > 1917 Lightweight Insulating Concrete Roofs > 1917.1 Lightweight Insulating Concrete > 1917.1.2 Cellular Lightweight Insulating Concrete
JUMP TO FULL CODE CHAPTER
Insulating concrete formulated by mixing a hydrated cementitious matrix around noninterconnecting air cells created by the addition of preformed foam formed from hydrolyzed proteins or synthetic surfactants. The cured cellular lightweight insulating concrete shall have minimum compressive strength of 160 psi (1103 kPa) when tested in compliance with ASTM C495 and C796.

Related Code Sections


1917.1.2 Concrete, Cellular Lightweight Insulating Concrete
formed from hydrolyzed proteins or synthetic surfactants. The cured cellular lightweight insulating concrete shall have minimum compressive strength ...
2014 FBC - Building, 5th edition > 19 Concrete > 1917 Lightweight Insulating Concrete Roofs > 1917.1 Lightweight Insulating Concrete > 1917.1.2 Cellular Lightweight Insulating Concrete
1917.1.2 Concrete, Cellular Lightweight Insulating Concrete
formed from hydrolyzed proteins or synthetic surfactants. The cured cellular lightweight insulating concrete shall have minimum compressive strength ...
2020 FBC - Building, 7th edition > 19 Concrete > 1917 Lightweight Insulating Concrete Roofs > 1917.1 Lightweight Insulating Concrete > 1917.1.2 Cellular Lightweight Insulating Concrete
1917.1.2 Concrete, Cellular Lightweight Insulating Concrete
formed from hydrolyzed proteins or synthetic surfactants. The cured cellular lightweight insulating concrete shall have minimum compressive strength ...
2017 FBC - Building, 6th edition > 19 Concrete > 1917 Lightweight Insulating Concrete Roofs > 1917.1 Lightweight Insulating Concrete > 1917.1.2 Cellular Lightweight Insulating Concrete
1917.1.3 Concrete, Cellular/Aggregate (Hybrid) Lightweight Insulating Concrete
Insulated concrete formulated by combining preformed foam with low density aggregates to impart properties of both aggregate and cellular lightweight ...
2014 FBC - Building, 5th edition > 19 Concrete > 1917 Lightweight Insulating Concrete Roofs > 1917.1 Lightweight Insulating Concrete > 1917.1.3 Cellular/Aggregate (Hybrid) Lightweight Insulating Concrete
Section 1917 Concrete, Lightweight Insulating Concrete Roofs
of preformed foam formed from hydrolyzed proteins or synthetic surfactants. The cured cellular lightweight insulating concrete shall have minimum ...
2020 FBC - Building, 7th edition > 19 Concrete > 1917 Lightweight Insulating Concrete Roofs
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING