// CODE SNIPPET
R802.5.2.1 Ceiling Joists Lapped
JUMP TO FULL CODE CHAPTER
Ends of ceiling joists shall be lapped not less than 3 inches (76 mm) or butted over bearing partitions or beams and toenailed to the bearing member. Where ceiling joists are used to provide resistance to rafter thrust, lapped joists shall be nailed together in accordance with Table R802.5.2 and butted joists shall be tied together in a manner to resist such thrust. Joists that do not resist thrust shall be permitted to be nailed in accordance with Table R602.3(1). Wood structural panel roof sheathing, in accordance with Table R503.2.1.1(1), shall not cantilever more than 9 inches (229 mm) beyond the gable endwall unless supported by gable overhang framing.
Related Code Sections
R802.5.2.1 Roof-Ceiling Construction, Ceiling Joists Lapped
Ends of ceiling joists shall be lapped not less than 3 inches (76 mm) or butted over bearing partitions or beams and toenailed to the bearing member ...
Residential Code 2018 of Kansas > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.5 Ceiling Joists > R802.5.2 Ceiling Joist and Rafter Connections > R802.5.2.1 Ceiling Joists Lapped
2308.7.3.1 Wood, Ceiling Joist and Rafter Connections
in span.
Equivalent nailing patterns are required for ceiling joist to ceiling joist lap splices.
Connected members shall be of sufficient size ...
Building Code 2018 of Kansas > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.7 Roof and Ceiling Framing > 2308.7.3 Ceiling Joist and Rafter Framing > 2308.7.3.1 Ceiling Joist and Rafter Connections
R804.3.1 Roof-Ceiling Construction, Ceiling Joists
Cold-formed steel ceiling joists shall be in accordance with this section ...
Residential Code 2018 of Kansas > 8 Roof-Ceiling Construction > R804 Cold-Formed Steel Roof Framing > R804.3 Roof Construction > R804.3.1 Ceiling Joists
(I) Equipment for General Use, Joists
In dry board applications, cable shall be installed parallel to the joist, leaving a clear space centered under the joist of 65 mm (2 1 / 2 ...
National Electrical Code 2017 of Kansas > 4 Equipment for General Use > 424 Fixed Electric Space-Heating Equipment > 424.41 Ceiling Installation of Heating Cables on Dry Board, in Plaster, and on Concrete > (I) Joists
R804.3.1.4 Roof-Ceiling Construction, Ceiling Joist Splicing
Splices in ceiling joists shall be permitted, if ceiling joist splices are supported at interior bearing points and are constructed in accordance ...
Residential Code 2018 of Kansas > 8 Roof-Ceiling Construction > R804 Cold-Formed Steel Roof Framing > R804.3 Roof Construction > R804.3.1 Ceiling Joists > R804.3.1.4 Ceiling Joist Splicing