1926.1124(k)(7) CBD Diagnostic Center
JUMP TO FULL CODE CHAPTER
The employer must provide an evaluation at no cost to the employee at a CBD diagnostic center that is mutually agreed upon by the employer and the employee. The examination must be provided within 30 days of:
The employer's receipt of a physician's written medical opinion to the employer that recommends referral to a CBD diagnostic center; or
The employee presenting to the employer a physician's written medical report indicating that the employee has been confirmed positive or diagnosed with CBD, or recommending referral to a CBD diagnostic center.
The employer must obtain a written medical opinion from the CBD diagnostic center within 30 days of the medical examination. The written medical opinion must contain only the information in paragraph (k)(6)(i) of this standard, as applicable, unless the employee provides written authorization to release additional information. If the employee provides written authorization, the written opinion must also contain the information from paragraphs (k)(6)(ii), (iv), and (v), if applicable.
The employer must ensure that each employee receives a copy of the written medical opinion from the CBD diagnostic center described in paragraph (k)(7) of this standard within 30 days of any medical examination performed for that employee.
After an employee has received the initial clinical evaluation at a CBD diagnostic center described in paragraph (k)(7)(i) of this standard, the employee may choose to have any subsequent medical examinations for which the employee is eligible under paragraph (k) of this standard performed at a CBD diagnostic center mutually agreed upon by the employer and the employee, and the employer must provide such examinations at no cost to the employee.
The employer must ensure that the employee receives a written medical report from the CBD diagnostic center that contains all the information required in paragraphs (k)(5)(i), (ii), (iv), and (v) of this standard and that the PLHCP explains the results of the examination to the employee within 30 days of the examination.
Related Code Sections
1926.1124(k)(7) Toxic and Hazardous Substances, CBD Diagnostic Center
The employer must provide an evaluation at no cost to the employee at a CBD diagnostic center that is mutually agreed upon by the employer ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1124 Beryllium > 1926.1124(k) Medical Surveillance > 1926.1124(k)(7) CBD Diagnostic Center
1926.1124(k)(7)(ii) Toxic and Hazardous Substances,
The employer must ensure that the employee receives a written medical report from the CBD diagnostic center that contains all the information ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1124 Beryllium > 1926.1124(k) Medical Surveillance > 1926.1124(k)(7) CBD Diagnostic Center > 1926.1124(k)(7)(ii)
1926.1124(k)(7)(iii) Toxic and Hazardous Substances,
The employer must obtain a written medical opinion from the CBD diagnostic center within 30 days of the medical examination. The written medical ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1124 Beryllium > 1926.1124(k) Medical Surveillance > 1926.1124(k)(7) CBD Diagnostic Center > 1926.1124(k)(7)(iii)
1926.1124(k)(5)(iii) Toxic and Hazardous Substances,
contain a referral for an evaluation at a CBD diagnostic center ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1124 Beryllium > 1926.1124(k) Medical Surveillance > 1926.1124(k)(5) Licensed Physician's Written Medical Report for the Employee > 1926.1124(k)(5)(iii)
1926.1124(k)(6)(iii) Toxic and Hazardous Substances,
written authorization, the written opinion must also contain a referral for an evaluation at a CBD diagnostic center ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1124 Beryllium > 1926.1124(k) Medical Surveillance > 1926.1124(k)(6) Licensed Physician's Written Medical Opinion for the Employer > 1926.1124(k)(6)(iii)