• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

705.16.3 Cast-Iron Pipe to Galvanized Steel Pipe

Plumbing Code 2018 of Colorado > 7 Sanitary Drainage > 705 Joints > 705.16 Joints Between Different Materials > 705.16.3 Cast-Iron Pipe to Galvanized Steel Pipe
JUMP TO FULL CODE CHAPTER
Joints between cast-iron and galvanized steel shall be made by either caulked or threaded joints or with an approved adapter fitting.

Related Code Sections


512.2 Exhaust Systems, Materials
, or any of the following piping materials that comply with the International Plumbing Code as building sanitary drainage and vent pipe: cast iron ...
Mechanical Code 2015 of Colorado > 5 Exhaust Systems > 512 Subslab Soil Exhaust Systems > 512.2 Materials
512.2 Exhaust Systems, Materials
, or any of the following piping materials that comply with the International Plumbing Code as building sanitary drainage and vent pipe: cast iron ...
Mechanical Code 2018 of Colorado > 5 Exhaust Systems > 512 Subslab Soil Exhaust Systems > 512.2 Materials
23.4.4.7 Plans and Calculations, Friction Loss
Cement-lined cast- or ductile iron 140 Copper tube or stainless steel 150 Asbestos cement 140 Concrete 140 *The ...
Standard for the Installation of Sprinkler Systems 2013 of Colorado > 23 Plans and Calculations > 23.4 Hydraulic Calculation Procedures > 23.4.4* Calculation Procedure > 23.4.4.7 Friction Loss
Section 305 General Regulations, Piping Support
In concealed locations where piping, other than cast-iron or steel, is installed through holes or notches in studs, joists, rafters or similar ...
Mechanical Code 2018 of Colorado > 3 General Regulations > 305 Piping Support
10.1* Underground Piping, Piping Materials
of Ductile Iron Water Mains and Their Appurtenances AWWA C600 Steel Steel Water Pipe 6 in. and Larger AWWA C200 Coal-Tar ...
Standard for the Installation of Sprinkler Systems 2013 of Colorado > 10 Underground Piping > 10.1* Piping Materials
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE