// CODE SNIPPET
705.16.3 Cast-Iron Pipe to Galvanized Steel or Brass Pipe
JUMP TO FULL CODE CHAPTER
Joints between cast-iron and galvanized steel or brass pipe shall be made by either caulked or threaded joints or with an approved adapter fitting.
Related Code Sections
705.16.3 Sanitary Drainage, Cast-Iron Pipe to Galvanized Steel or Brass Pipe
Joints between cast-iron and galvanized steel or brass pipe shall be made by either caulked or threaded joints or with an approved adapter fitting ...
2017 FBC - Plumbing, 6th edition > 7 Sanitary Drainage > 705 Joints > 705.16 Joints Between Different Materials > 705.16.3 Cast-Iron Pipe to Galvanized Steel or Brass Pipe
705.19.3 Sanitary Drainage, Cast-Iron Pipe to Galvanized Steel or Brass Pipe
Joints between cast-iron and galvanized steel or brass pipe shall be made by either caulked or threaded joints or with an approved adapter fitting ...
2014 FBC - Plumbing, 5th edition > 7 Sanitary Drainage > 705 Joints > 705.19 Joints Between Different Materials > 705.19.3 Cast-Iron Pipe to Galvanized Steel or Brass Pipe
P3003.18.3 Sanitary Drainage, Cast-Iron Pipe to Galvanized Steel or Brass Pipe
Joints between cast-iron and galvanized steel or brass pipe shall be made by either caulked or threaded joints or with an approved adapter fitting ...
2014 FBC - Residential, 5th edition > 30 Sanitary Drainage > P3003 Joints and Connections > P3003.18 Joints Between Different Materials > P3003.18.3 Cast-Iron Pipe to Galvanized Steel or Brass Pipe
P3003.13.3 Sanitary Drainage, Cast-Iron Pipe to Galvanized Steel or Brass Pipe
Joints between cast-iron and galvanized steel or copper-alloy pipe shall be made by either caulked or threaded joints or with an approved adapter ...
2017 FBC - Residential, 6th edition > 30 Sanitary Drainage > P3003 Joints and Connections > P3003.13 Joints Between Different Materials > P3003.13.3 Cast-Iron Pipe to Galvanized Steel or Brass Pipe
512.2 Exhaust Systems, Materials
; galvanized steel; brass or copper pipe; copper tube of a weight not less than that of copper drainage tube, Type DWV; and plastic piping ...
2017 FBC - Mechanical, 6th edition > 5 Exhaust Systems > 512 Subslab Soil Exhaust Systems > 512.2 Materials