• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1519.6 Cast-In-Place and Precast Structural Concrete Decks

2014 FBC - Building, 5th edition > 15 Roof Assemblies and Rooftop Structures > 1519 High-Velocity Hurricane Zones— Roof Coverings With Slopes Less Than 2:12 > 1519.6 Cast-In-Place and Precast Structural Concrete Decks
JUMP TO FULL CODE CHAPTER
Cast-in-place and precast structural concrete decks are considered nonnailable. Concrete decks shall be clean, dry and fully primed with ASTM D 41 or ASTM D 43, as required, primer applied at a rate of not less than 1 gallon (3.8 L) per square. Hot asphalt or cold adhesive shall not be applied until the primer has fully dried.

1519.6.1 Reserved

Related Code Sections


1519.6 Roof Assemblies and Rooftop Structures, Cast-In-Place and Precast Structural Concrete Decks
Cast-in-place and precast structural concrete decks are considered nonnailable. Concrete decks shall be clean, dry and fully primed with ASTM D41 ...
2017 FBC - Building, 6th edition > 15 Roof Assemblies and Rooftop Structures > 1519 High-Velocity Hurricane Zones— Roof Coverings With Slopes Less Than 2:12 > 1519.6 Cast-In-Place and Precast Structural Concrete Decks
1519.6 Roof Assemblies and Rooftop Structures, Cast-In-Place and Precast Structural Concrete Decks
Cast-in-place and precast structural concrete decks are considered nonnailable. Concrete decks shall be clean, dry and fully primed with ASTM D41 ...
2020 FBC - Building, 7th edition > 15 Roof Assemblies and Rooftop Structures > 1519 High-Velocity Hurricane Zones—Roof Coverings With Slopes Less Than 2:12 > 1519.6 Cast-In-Place and Precast Structural Concrete Decks
1519.6 Roof Assemblies and Rooftop Structures, Cast-In-Place and Precast Structural Concrete Decks
Cast-in-place and precast structural concrete decks are considered nonnailable. Concrete decks shall be clean, dry and fully primed with ASTM D 41 ...
2014 FBC - Building, 5th edition > 15 Roof Assemblies and Rooftop Structures > 1519 High-Velocity Hurricane Zones— Roof Coverings With Slopes Less Than 2:12 > 1519.6 Cast-In-Place and Precast Structural Concrete Decks
722.2.1.1 Fire and Smoke Protection Features, Cast-In-Place or Precast Walls
apply to plain, reinforced or prestressed concrete walls. TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS ...
2014 FBC - Building, 5th edition > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.2 Concrete Assemblies > 722.2.1 Concrete Walls > 722.2.1.1 Cast-In-Place or Precast Walls
722.2.1.1 Fire and Smoke Protection Features, Cast-In-Place or Precast Walls
apply to plain, reinforced or prestressed concrete walls. TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS ...
2017 FBC - Building, 6th edition > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.2 Concrete Assemblies > 722.2.1 Concrete Walls > 722.2.1.1 Cast-In-Place or Precast Walls
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE