1926.1101(l)(3) Care of Asbestos-Containing Flooring Material
JUMP TO FULL CODE CHAPTER
All vinyl and asphalt flooring material shall be maintained in accordance with this paragraph unless the building/facility owner demonstrates, pursuant to paragraph (g)(8)(i)(I) of this section that the flooring does not contain asbestos.
Stripping of finishes shall be conducted using low abrasion pads at speeds lower than 300 rpm and wet methods.
Burnishing or dry buffing may be performed only on flooring which has sufficient finish so that the pad cannot contact the flooring material.
Sanding of flooring material is prohibited.
Related Code Sections
1926.1101(l)(3) Toxic and Hazardous Substances, Care of Asbestos-Containing Flooring Material
, pursuant to paragraph (g)(8)(i)(I) of this section that the flooring does not contain asbestos ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(l) Housekeeping > 1926.1101(l)(3) Care of Asbestos-Containing Flooring Material
1926.1101(l) Toxic and Hazardous Substances, Housekeeping
Asbestos waste, scrap, debris, bags, containers, equipment, and contaminated clothing consigned for disposal shall be collected and disposed of in sealed ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(l) Housekeeping
1926.1101(k)(1)(i) Toxic and Hazardous Substances,
) of this section that the material is not asbestos-containing. Asphalt and vinyl flooring material installed no later than 1980 must also be considered as asbestos ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(k) Communication of Hazards > 1926.1101(k)(1) Hazard Communication > 1926.1101(k)(1)(i)
1926.1101(k)(9)(vi) Toxic and Hazardous Substances,
insulation and surfacing ACM/PACM, and asbestos-containing flooring material, or flooring material where the absence of asbestos has not yet been ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(k) Communication of Hazards > 1926.1101(k)(9) Employee Information and Training > 1926.1101(k)(9)(vi)
1926.1101(k)(1) Toxic and Hazardous Substances, Hazard Communication
) of this section that the material is not asbestos-containing. Asphalt and vinyl flooring material installed no later than 1980 must also be considered as asbestos ...
OSHA 1926 Construction > Z Toxic and Hazardous Substances > 1926.1101 Asbestos > 1926.1101(k) Communication of Hazards > 1926.1101(k)(1) Hazard Communication