// CODE SNIPPET
608.17.1.1 Carbonated Beverage Dispensers
JUMP TO FULL CODE CHAPTER
The water supply connection to each carbonated beverage dispenser shall be protected against backflow by a backflow preventer conforming to ASSE 1022 or by an air gap. The portion of the backflow preventer device downstream from the second check valve of the device and the piping downstream therefrom shall not be affected by carbon dioxide gas.
Related Code Sections
608.17.1.1 Water Supply and Distribution, Carbonated Beverage Dispensers
The water supply connection to each carbonated beverage dispenser shall be protected against backflow by a backflow preventer conforming to ASSE 1022 ...
Plumbing Code 2018 of Utah > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.17 Connections to the Potable Water System > 608.17.1 Beverage Dispensers > 608.17.1.1 Carbonated Beverage Dispensers
105.6.8 Scope and Administration, Compressed Gases
875 (100 lbs.) Carbon dioxide used in insulated liquid carbon dioxide beverage dispensing applications 875 (100 lbs.) Corrosive 200 ...
Fire Code 2018 of Utah > 1 Scope and Administration > 105 Permits > 105.6 Required Operational Permits > 105.6.8 Compressed Gases
5307.3 Compressed Gases, Insulated Liquid Carbon Dioxide Systems Used in Beverage Dispensing Applications
Insulated liquid carbon dioxide systems with more than 100 pounds (45.4 kg) of carbon dioxide used in beverage dispensing applications shall comply ...
Fire Code 2018 of Utah > 53 Compressed Gases > 5307 Compressed Gases Not Otherwise Regulated > 5307.3 Insulated Liquid Carbon Dioxide Systems Used in Beverage Dispensing Applications
608.16.1 Water Supply and Distribution, Beverage Dispensers
The water supply connection to beverage dispensers shall be protected against backflow by a backflow preventer conforming to ASSE 1022 or by an air ...
Plumbing Code 2015 of Utah > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.16 Connections to the Potable Water System > 608.16.1 Beverage Dispensers
Section 5307 Compressed Gases, Compressed Gases Not Otherwise Regulated
containing insulated liquid carbon dioxide systems used in beverage dispensing applications shall comply with Section 5307.3 ...