• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R506.2.3.1 Capillary Break

California Residential Code 2016 > 5 Floors > R506 Concrete Floors (On Ground) > R506.2 Site Preparation > R506.2.3 Vapor Retarder > R506.2.3.1 Capillary Break
JUMP TO FULL CODE CHAPTER
When a vapor retarder is required, a capillary break shall be installed in accordance with the California Green Building Standards Code, Chapter 4, Division 4.5.

Related Code Sections


4.505.2.1 Residential Mandatory Measures, Capillary Break
A capillary break shall be installed in compliance with at least one of the following: A 4-inch-thick (101.6 mm) base of 1 / 2 inch (12.7 mm ...
California Green Building Standards Code 2019 > 4 Residential Mandatory Measures > 4.505 Interior Moisture Control > 4.505.2 Concrete Slab Foundations > 4.505.2.1 Capillary Break
4.505.2.1 Residential Mandatory Measures, Capillary Break
A capillary break shall be installed in compliance with at least one of the following: A 4-inch-thick (101.6 mm) base of 1 / 2 inch (12.7 mm ...
California Green Building Standards Code 2016 > 4 Residential Mandatory Measures > 4.505 Interior Moisture Control > 4.505.2 Concrete Slab Foundations > 4.505.2.1 Capillary Break
R506.2.3.1 Floors, Capillary Break
When a vapor retarder is required, a capillary break shall be installed in accordance with the California Green Building Standards Code, Chapter 4 ...
California Residential Code 2016 > 5 Floors > R506 Concrete Floors (On Ground) > R506.2 Site Preparation > R506.2.3 Vapor Retarder > R506.2.3.1 Capillary Break
R506.2.3.1 Floors, Capillary Break
When a vapor retarder is required, a capillary break shall be installed in accordance with the California Green Building Standards Code , Chapter 4 ...
California Residential Code 2019 > 5 Floors > R506 Concrete Floors (On Ground) > R506.2 Site Preparation > R506.2.3 Vapor Retarder > R506.2.3.1 Capillary Break
1907.1.1 Concrete, [HCD 1] Capillary Break
When a vapor retarder is required, a capillary break shall be installed in accordance with the California Green Building Standards Code (CALGreen ...
California Building Code 2016 (Vol 1 & 2) > 19 Concrete > 1907 Minimum Slab Provisions > 1907.1 General > 1907.1.1 [HCD 1] Capillary Break
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING