• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1431(d)(3) Capacity: Hoisting Personnel Without a Personnel Platform

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(d) Equipment Criteria > 1926.1431(d)(3) Capacity: Hoisting Personnel Without a Personnel Platform
JUMP TO FULL CODE CHAPTER
When hoisting personnel without a personnel platform pursuant to paragraph (b)(2) of this section, the total load (including the hook, load line, rigging and any other equipment that imposes a load) must not exceed 50 percent of the rated capacity for the radius and configuration of the equipment, except during proof testing.

Related Code Sections


1926.1431(d)(3) Cranes & Derricks in Construction, Capacity: Hoisting Personnel Without a Personnel Platform
When hoisting personnel without a personnel platform pursuant to paragraph (b)(2) of this section, the total load (including the hook, load line ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(d) Equipment Criteria > 1926.1431(d)(3) Capacity: Hoisting Personnel Without a Personnel Platform
1926.552(c) Helicopters, Hoists, Elevators, and Conveyors, Personnel Hoists
covering of 2-inch planking, 3/4-inch plywood or other solid material or equivalent strength shall be provided on the top of every personnel hoist ...
OSHA 1926 Construction > N Helicopters, Hoists, Elevators, and Conveyors > 1926.552 Material Hoists, Personnel Hoists, and Elevators > 1926.552(c) Personnel Hoists
1926.1441(j) Cranes & Derricks in Construction, Hoisting Personnel
The employer must ensure that equipment covered by this section is not used to hoist personnel ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1441 Equipment With a Rated Hoisting/Lifting Capacity of 2,000 Pounds or Less > 1926.1441(j) Hoisting Personnel
1926.1431(k)(6) Cranes & Derricks in Construction, Platforms Without Controls
Where the platform is not equipped with controls, the equipment operator must remain at the equipment controls, on site, and in view of the equipment ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(k) Work Practices > 1926.1431(k)(6) Platforms Without Controls
1926.1431(e)(12) Cranes & Derricks in Construction,
The weight of the platform and its rated capacity must be conspicuously posted on the platform with a plate or other permanent marking ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(e) Personnel Platform Criteria > 1926.1431(e)(12)
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE