2.16.3 Capacity and Data Plates
Go To Full Code Chapter
2.16.3.1 Plates Required and Locations
Every elevator shall be provided with a capacity plate and a data plate complying with 8.13.1.
The capacity plate shall be located in a conspicuous position inside the car.
The data plate shall be located on the car crosshead, or for elevators having no crosshead or no exposed crosshead, in a conspicuous location on the car top or inside the car.
2.16.3.2 Information Required on Plates
2.16.3.2.1
Capacity plates shall indicate the rated load of the elevator in kilograms or pounds or both (see Nonmandatory Appendix D), and, in addition, this plate or a separate plate shall indicate
(b) for freight elevators designed for Class C2 loading, the maximum load the elevator is designed to support while being loaded or unloaded [see 2.16.2.2.4(c)]
2.16.3.2.2
Data plates shall indicate
(a) the weight of the complete car, including the car safety and all auxiliary equipment attached to the car
(b) the rated load and speed
(c) the suspension means data required by 2.20.2.1
(d) the name or trademark of the manufacturer and the year manufactured
(e) rail lubrication instructions (see 2.17.16)
(f) the percent counterweight overbalance range (see 2.24.2.3.5)
2.16.3.3 Material and Marking of Permanent Plates
Plates shall comply with 8.13.1.
Related Code Sections
2.16.3 Electric Elevators, Capacity and Data Plates
Every elevator shall be provided with a capacity plate and a data plate complying with 8.13.1. The capacity plate shall be located in a conspicuous ...
3.16.3 Hydraulic Elevators, Capacity and Data Plates
The requirements of 2.16.3 shall apply, except (a) requirement 2.16.3.2.1(a) shall not apply to hydraulic elevators. (b) on data plates (see ...
5.2.1.16.2 Special Application Elevators, Capacity and Data Plates
(a) Capacity plates shall indicate the rated load of the elevator in kilograms, pounds, or both. (b) Data plates shall conform to 2.16.3.2.2 ...
5.7.12.1 Special Application Elevators, Capacity and Data Plates
Capacity and data plates, conforming to 2.16.3, shall be provided ...
5.10.1.23 Special Application Elevators, Capacity and Data Plates or Signs
Every elevator car shall be provided with a capacity plate or sign and a data plate or sign temporarily fastened in place. The capacity plate or sign ...