R802.7.1.1 Cantilevered Portions of Rafters
JUMP TO FULL CODE CHAPTER

Notches on cantilevered portions of rafters are permitted provided the dimension of the remaining portion of the rafter is not less than 31/2 inches (89 mm) and the length of the cantilever does not exceed 24 inches (610 mm) in accordance with Figure R802.7.1.1.
For SI: 1 inch = 25.4 mm.
RAFTER NOTCH
Related Code Sections
R802.7.1.1 Roof-Ceiling Construction, Cantilevered Portions of Rafters
Notches on cantilevered portions of rafters are permitted provided the dimension of the remaining portion of the rafter is not less than 3 1 / 2 ...
Residential Code 2018 of Kansas > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.7 Cutting, Drilling and Notching > R802.7.1 Sawn Lumber > R802.7.1.1 Cantilevered Portions of Rafters
R502.3.3 Floors, Floor Cantilevers
Floor cantilever spans shall not exceed the nominal depth of the wood floor joist. Floor cantilevers constructed in accordance with Table R502.3.3(1 ...
Residential Code 2018 of Kansas > 5 Floors > R502 Wood Floor Framing > R502.3 Allowable Joist Spans > R502.3.3 Floor Cantilevers
R505.3.3.4 Floors, Blocking at Cantilevers
Blocking shall be installed between every other joist over cantilever bearing supports in accordance with Figure R505.3.1(4), R505.3.1(5) or R505.3.1 ...
Residential Code 2018 of Kansas > 5 Floors > R505 Cold-Formed Steel Floor Framing > R505.3 Floor Construction > R505.3.3 Joist Bracing and Blocking > R505.3.3.4 Blocking at Cantilevers
2306.1.1 Wood, Joists and Rafters
The design of rafter spans is permitted to be in accordance with the AWC STJR ...
Building Code 2018 of Kansas > 23 Wood > 2306 Allowable Stress Design > 2306.1 Allowable Stress Design > 2306.1.1 Joists and Rafters
2308.7.2 Wood, Rafter Spans
Spans for rafters shall be in accordance with Table 2308.7.2(1), 2308.7.2(2), 2308.7.2(3), 2308.7.2(4), 2308.7.2(5) or 2308.7.2(6). For other grades ...
Building Code 2018 of Kansas > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.7 Roof and Ceiling Framing > 2308.7.2 Rafter Spans