A5.601.3 CALGreen Tier 2
JUMP TO FULL CODE CHAPTER
For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards.
Comply with the energy efficiency requirements in Section A5.203.1.1 and Section A5.203.1.2.2.
In addition to the provisions of Sections A5.601.3.1 and A5.601.3.3 above, compliance with the following voluntary measures from Appendix A5 and additional elective measures shown in Table A5.601.3.4 is required for Tier 2:
- From Division A5.1,
- Comply with the designated parking requirements for fuel efficient vehicles for a minimum of 12 percent of parking capacity per Section A5.106.5.1 and Table A5.106.5.1.2.
- Comply with thermal emittance, solar reflectance or SRI values for cool roofs in Section A5.106.11.2 and Table A5.106.11.2.2.1
- Comply with three elective measures selected from this division.
- From Division A5.2 comply with ONE of the following:
- Outdoor lighting as described in A5.203.1.1.1.
- Service water heating in restaurants as described in A5.203.1.1.2.
- Warehouse Dock Seal Doors A5.203.1.1.3.
- Daylight Design Power Adjustments 5.203.1.1.4.
- Exhaust Air Heat Recovery A5.203.1.1.5.
- From Division A5.3,
- Comply with the 20-percent reduction for indoor potable water use in Section A5.303.2.3.2.
- Comply with three elective measures selected from this division.
- From Division A5.4,2
- Comply with recycled content of 15 percent of materials based on estimated total cost, or use two products from Table A5.405.4 for at least 75 percent by cost in Section A5.405.4.1.
- Comply with the 80-percent reduction in construction and demolition waste in Section A5.408.3.1.
- Comply with three elective measures selected from this division.
- From Division A5.5,
- Comply with resilient flooring systems for 100 percent of resilient flooring in Section A5.504.4.7.1.
Exception: Allowance may be permitted in Tier 2 for up to 5-percent specialty purpose flooring.
- Comply with thermal insulation meeting 2009 CHPS low-emitting materials list and no added formaldehyde in Section A5.504.4.8.1.
- Comply with three elective measures selected from this division.
- Comply with resilient flooring systems for 100 percent of resilient flooring in Section A5.504.4.7.1.
- Comply with three additional elective measures selected from any division.
- 1 Cool roof is required for compliance with Tiers 1 and 2 and may be used to meet energy standards in Part 6, exceed energy standards and to mitigate heat island effect.
- 2 Life cycle assessment compliant with Section A5.409.4 in this code may be substituted for prescriptive measures from Division A5.4.
Related Code Sections
305.1.2 Green Building, CALGreen Tier 2
To achieve CALGreen Tier 2, buildings must exceed the latest edition of "Savings By Design, Healthcare Modeling Procedures" by a minimum of 15 ...
California Green Building Standards Code 2019 > 3 Green Building > 305 [OSHPD 1] CALGreen Tier 1 and CALGreen Tier 2 > 305.1 > 305.1.2 CALGreen Tier 2
305.1.2 Green Building, CALGreen Tier 2
To achieve CALGreen Tier 2, buildings must exceed the latest edition of "Savings By Design, Healthcare Modeling Procedures" by a minimum of 15 ...
California Green Building Standards Code 2016 > 3 Green Building > 305 [OSHPD 1] CALGreen Tier 1 and CALGreen Tier 2 > 305.1 > 305.1.2 CALGreen Tier 2
A5.203.2.2 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], CALGreen Tier 2
[OSHPD 1] To achieve CALGreen Tier 2, buildings must exceed the latest edition of "Savings By Design, Healthcare Modeling Procedures" by a minimum ...
California Green Building Standards Code 2019 > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.203 Performance Approach > A5.203.2 Energy Performance > A5.203.2.2 CALGreen Tier 2
A5.203.2.2 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4], CALGreen Tier 2
[OSHPD 1] To achieve CALGreen Tier 2, buildings must exceed the latest edition of "Savings By Design, Healthcare Modeling Procedures" by a minimum ...
California Green Building Standards Code 2016 > A6.1 — Voluntary Standards for Health Facilities [OSHPD 1, 2 & 4] > A5.203 Performance Approach > A5.203.2 Energy Performance > A5.203.2.2 CALGreen Tier 2
A5.601.3 Nonresidential Voluntary Measures, CALGreen Tier 2
elective measures shown in Table A5.601.3.4 is required for Tier 2:
From Division A5.1,
Comply with the designated parking requirements ...
California Green Building Standards Code 2019 > A5 Nonresidential Voluntary Measures > A5.601 CALGreen Tier 1 and Tier 2 > A5.601.3 CALGreen Tier 2