Appendix F Calculations and Application of Age Corrections to Audiograms
Go To Full Code Chapter
This Appendix Is Non-Mandatory
In determining whether a standard threshold shift has occurred, allowance may be made for the contribution of aging to the change in hearing level by adjusting the most recent audiogram. If the employer chooses to adjust the audiogram, the employer shall follow the procedure described below. This procedure and the age correction tables were developed by the National Institute for Occupational Safety and Health in the criteria document entitled "Criteria for a Recommended Standard . . .
Occupational Exposure to Noise," ((HSM)-11001)
For each audiometric test frequency;
In determining whether a standard threshold shift has occurred, allowance may be made for the contribution of aging to the change in hearing level by adjusting the most recent audiogram. If the employer chooses to adjust the audiogram, the employer shall follow the procedure described below. This procedure and the age correction tables were developed by the National Institute for Occupational Safety and Health in the criteria document entitled "Criteria for a Recommended Standard . . .
Occupational Exposure to Noise," ((HSM)-11001)
For each audiometric test frequency;
- Determine from Tables F-1 or F-2 the age correction values for the employee by:
- Finding the age at which the most recent audiogram was taken and recording the corresponding values of age corrections at 1000 Hz through 6000 Hz;
- Finding the age at which the baseline audiogram was taken and recording the corresponding values of age corrections at 1000 Hz through 6000 Hz
- Subtract the values found in step (i)(B) from the value found in step (i)(A)
- The differences calculated in step (ii) represented that portion of the change in hearing that may be due to aging.
EXAMPLE: Employee is a 32-year-old male. The audiometric history for his right ear is shown in decibels below.
Employee's age Audiometric test frequency (Hz) 1000 2000 3000 4000 6000 26 10 5 5 10 5 *27 0 0 0 5 5 28 0 0 0 10 5 29 5 0 5 15 5 30 0 5 10 20 10 31 5 10 20 15 15 *32 5 10 10 25 20
The audiogram at age 27 is considered the baseline since it shows the best hearing threshold levels. Asterisks have been used to identify the baseline and most recent audiogram. A threshold shift of 20 dB exists at 4000 Hz between the audiograms taken at ages 27 and 32.
(The threshold shift is computed by subtracting the hearing threshold at age 27, which was 5, from the hearing threshold at age 32, which is 25). A retest audiogram has confirmed this shift. The contribution of aging to this change in hearing may be estimated in the following manner:
Go to Table F-1 and find the age correction values (in dB) for 4000 Hz at age 27 and age 32
Frequency (Hz) 1000 2000 3000 4000 6000 Age 32 6 5 7 10 14 Age 27 5 4 6 7 11 Difference 1 1 1 3 3
The difference represents the amount of hearing loss that may be attributed to aging in the time period between the baseline audiogram and the most recent audiogram. In this example, the difference at 4000 Hz is 3 dB. This value is subtracted from the hearing level at 4000 Hz, which in the most recent audiogram is 25, yielding 22 after adjustment. Then the hearing threshold in the baseline audiogram at 4000 Hz (5) is subtracted from the adjusted annual audiogram hearing threshold at 4000 Hz (22). Thus the age-corrected threshold shift would be 17 dB (as opposed to a threshold shift of 20 dB without age correction)
TABLE F-1 - AGE CORRECTION VALUES IN DECIBELS FOR MALES Years Audiometric Test Frequency (Hz) 1000 2000 3000 4000 6000 20 or younger 5 3 4 5 8 21 5 3 4 5 8 22 5 3 4 5 8 23 5 3 4 6 9 24 5 3 5 6 9 25 5 3 5 7 10 26 5 4 5 7 10 27 5 4 6 7 11 28 6 4 6 8 11 29 6 4 6 8 12 30 6 4 6 9 12 31 6 4 7 9 13 32 6 5 7 10 14 33 6 5 7 10 14 34 6 5 8 11 15 35 7 5 8 11 15 36 7 5 9 12 16 37 7 6 9 12 17 38 7 6 9 13 17 39 7 6 10 14 18 40 7 6 10 14 19 41 7 6 10 14 20 42 8 7 11 16 20 43 8 7 12 16 21 44 8 7 12 17 22 45 8 7 13 18 23 46 8 8 13 19 24 47 8 8 14 19 24 48 9 8 14 20 25 49 9 9 15 21 26 50 9 9 16 22 27 51 9 9 16 23 28 52 9 10 17 24 29 53 9 10 18 25 30 54 10 10 18 26 31 55 10 11 19 27 32 56 10 11 20 28 34 57 10 11 21 29 35 58 10 12 22 31 36 59 11 12 22 32 37 60 or older 11 13 23 33 38
TABLE F-2 - AGE CORRECTION VALUES IN DECIBELS FOR FEMALES Years Audiometric Test Frequency (Hz) 1000 2000 3000 4000 6000 20 or younger 7 4 3 3 6 21 7 4 4 3 6 22 7 4 4 4 6 23 7 5 4 4 7 24 7 5 4 4 7 25 8 5 4 4 7 26 8 5 5 4 8 27 8 5 5 5 8 28 8 5 5 5 8 29 8 5 5 5 9 30 8 6 5 5 9 31 8 6 6 5 9 32 9 6 6 6 10 33 9 6 6 6 10 34 9 6 6 6 10 35 9 6 7 7 11 36 9 7 7 7 11 37 9 7 7 7 12 38 10 7 7 7 12 39 10 7 8 8 12 40 10 7 8 8 13 41 10 8 8 8 13 42 10 8 9 9 13 43 11 8 9 9 14 44 11 8 9 9 14 45 11 8 10 10 15 46 11 9 10 10 15 47 11 9 10 11 16 48 12 9 11 11 16 49 12 9 11 11 16 50 12 10 11 12 17 51 12 10 12 12 17 52 12 10 12 13 18 53 13 10 13 13 18 54 13 11 13 14 19 55 13 11 14 14 19 56 13 11 14 15 20 57 13 11 15 15 20 58 14 12 15 16 21 59 14 12 16 16 21 60 or older 14 12 16 17 22
Upcodes Diagrams
Related Code Sections
Appendix F Occupational Health and Environmental Control, Calculations and Application of Age Corrections to Audiograms
audiogram was taken and recording the corresponding values of age corrections at 1000 Hz through 6000 Hz;
Finding the age at which the baseline ...
1910.95(g)(6) Occupational Health and Environmental Control, Annual Audiogram
At least annually after obtaining the baseline audiogram, the employer shall obtain a new audiogram for each employee exposed at or above an 8-hour ...
1910.95(g)(7) Occupational Health and Environmental Control, Evaluation of Audiogram
Each employee's annual audiogram shall be compared to that employee's baseline audiogram to determine if the audiogram is valid and if a standard ...
1910.95(g)(9) Occupational Health and Environmental Control, Revised Baseline
An annual audiogram may be substituted for the baseline audiogram when, in the judgment of the audiologist, otolaryngologist or physician who ...
1910.95(g)(7)(i) Occupational Health and Environmental Control,
Each employee's annual audiogram shall be compared to that employee's baseline audiogram to determine if the audiogram is valid and if a standard ...