3308.5.3 Cables
JUMP TO FULL CODE CHAPTER
Vertical safety netting shall be secured to noncorrosive wire cable capable of withstanding a load of at least 200 pounds (90.7 kg) applied in any direction except upward. The cables shall be located at a height of 60 inches (1524 mm), 42 inches (1067 mm), 21 inches (533 mm), and 0 inches (0 mm) above the level of the floor or, where installed at the roof level, the roof. Where the vertical safety netting extends above 60 inches (1524 mm) in height, a cable shall also be placed at the top of the netting, with intermediate cables between the 60 inch (1524 mm) cable and the top cable as needed to satisfy the design requirements of Section 3308.3.
Exceptions: In lieu of a cable:
Exceptions: In lieu of a cable:
- At 60 inches (1524 mm) or above, a toprail made of wood, pipe, or structural angle meeting the requirements of Section 3308.7.3.
- At 42 inches (1067 mm) and 21 inches (533 mm), midrails made of wood, pipe, or structural angle meeting the requirements of Section 3308.7.3.
- At 0 inches (0 mm), a toeboard meeting the requirements of Sections 3308.7.2 and 3308.7.3, provided the net is secured to the toeboard.
Related Code Sections
3308.5.3 Safeguards During Construction or Demolition, Cables
Vertical safety netting shall be secured to noncorrosive wire cable capable of withstanding a load of at least 200 pounds (90.7 kg) applied in any ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3308 Protection of Unenclosed Perimeters > 3308.5 Vertical Safety Netting Systems > 3308.5.3 Cables
Section 2207 Steel, Steel Cable Structures
The design, fabrication and erection including related connections, and protective coatings of steel cables for buildings shall be in accordance ...
Section 2207 Steel, Steel Cable Structures
The design, fabrication and erection including related connections, and protective coatings of steel cables for buildings shall be in accordance ...
3007.8.1 Elevators and Conveying Systems, Protection of Wiring or Cables
Wires or cables that are located outside of the elevator hoistway and machine room and that provide normal or standby power, control signals ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3007 Fire Service Access Elevator > 3007.8 Electrical Power > 3007.8.1 Protection of Wiring or Cables
3008.9.1 Elevators and Conveying Systems, Protection of Wiring or Cables
Wires or cables that are located outside of the elevator hoistway, machine room, control room and control space and that provide normal or standby ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.9 Electrical Power > 3008.9.1 Protection of Wiring or Cables