E3802.6 Cable-Securing Means
JUMP TO FULL CODE CHAPTER
Cables shall be supported and secured by staples; cable ties listed and identified for securement and support; or straps, hangers or similar fittings designed and installed so as not to damage the cable. [320.30 (A), 330.30 (A), 334.30, 338.10 (B) (4), 340.10 (4)]
Related Code Sections
E3802.6 Wiring Methods, Cable-Securing Means
Cables shall be supported and secured by staples; cable ties listed and identified for securement and support; or straps, hangers or similar fittings ...
Residential Code 2018 of Kansas > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.6 Cable-Securing Means
E3904.3 Power and Lighting Distribution, Securing and Supporting
Raceways, cable assemblies, boxes, cabinets and fittings shall be securely fastened in place. (300.11 ...
Residential Code 2018 of Kansas > 39 Power and Lighting Distribution > E3904 General Installation Requirements > E3904.3 Securing and Supporting
E3907.8 Power and Lighting Distribution, Cables
Where cables are used, each cable shall be secured to the cabinet, panelboard, cutout box, or meter socket enclosure. [312.5(C)] Exception ...
Residential Code 2018 of Kansas > 39 Power and Lighting Distribution > E3907 Cabinets and Panelboards > E3907.8 Cables
E4304.5 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Installation of Conductors and Cables
as to not damage the cable. Nonmetallic cable ties and other nonmetallic accessories used to secure and support cables located in stud cavity ...
Residential Code 2018 of Kansas > 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits > E4304 Installation Requirements > E4304.5 Installation of Conductors and Cables
E3905.3 Power and Lighting Distribution, Nonmetallic Boxes
and metal-armored cables. (314.3 Exception No. 1) Where integral bonding means with a provision for attaching an equipment grounding jumper inside ...
Residential Code 2018 of Kansas > 39 Power and Lighting Distribution > E3905 Boxes, Conduit Bodies and Fittings > E3905.3 Nonmetallic Boxes