1910.268(l) Cable Fault Locating and Testing
JUMP TO FULL CODE CHAPTER
Employees involved in using high voltages to locate trouble or test cables shall be instructed in the precautions necessary for their own safety and the safety of other employees.
Before the voltage is applied, cable conductors shall be isolated to the extent practicable. Employees shall be warned, by such techniques as briefing and tagging at all affected locations, to stay clear while the voltage is applied.
Related Code Sections
1910.268(l) Special Industries, Cable Fault Locating and Testing
Employees involved in using high voltages to locate trouble or test cables shall be instructed in the precautions necessary for their own safety ...
OSHA 1910 General Industry > R Special Industries > 1910.268 Telecommunications > 1910.268(l) Cable Fault Locating and Testing
1910.269(t)(7) Special Industries, Protection Against Faults
Where a cable in a manhole or vault has one or more abnormalities that could lead to a fault or be an indication of an impending fault, the employer ...
OSHA 1910 General Industry > R Special Industries > 1910.269 Electric Power Generation, Transmission, and Distribution > 1910.269(t) Underground Electrical Installations > 1910.269(t)(7) Protection Against Faults
1910.269(n) Special Industries, Grounding for the Protection of Employees
The employer shall ensure that, when an employee performs work on a cable at a location remote from the cable terminal, the cable is not grounded ...
OSHA 1910 General Industry > R Special Industries > 1910.269 Electric Power Generation, Transmission, and Distribution > 1910.269(n) Grounding for the Protection of Employees
1910.269(t) Special Industries, Underground Electrical Installations
identify the cable to be worked by electrical means, unless its identity is obvious by reason of distinctive appearance or location or by other readily ...
OSHA 1910 General Industry > R Special Industries > 1910.269 Electric Power Generation, Transmission, and Distribution > 1910.269(t) Underground Electrical Installations
1910.269(t)(7)(ii) Special Industries,
If the work employees will perform in a manhole or vault could cause a fault in a cable, the employer shall deenergize that cable before any employee ...
OSHA 1910 General Industry > R Special Industries > 1910.269 Electric Power Generation, Transmission, and Distribution > 1910.269(t) Underground Electrical Installations > 1910.269(t)(7) Protection Against Faults > 1910.269(t)(7)(ii)