• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1004.8 Burner Controls

NYC Mechanical Code 2008 > 10 Boilers, Water Heaters and Pressure Vessels > 1004 Boilers > 1004.8 Burner Controls
JUMP TO FULL CODE CHAPTER
Gas and oil modulating burners shall be provided with burner controls (oil and gas equivalent ratings) in accordance with Table 1004.8.

TABLE 1004.8
MINIMUM CONTROL REQUIREMENTS
TYPE OF CONTROL GROSS OUTPUT FIRING RATE OF THE BOILER OR
THE BURNER OIL DELIVERY RATE (gph), WHICHEVER IS GREATER
Combustion Controls #6 Oil #4 Oil #2 Oil
On-Off - - <10
Low-High-Off with low fire start 20 to <30 10 to <30 10 to <30
Low-High-Low-Off with proven low fire star 30 to <50 30 to <50 30 to <50
Full Modulation with proven low fire start 50 50 50
Full Modulation with proven low fire start as well as cross-limited oxygen trim (dry cell electrochemical type) 350 350 350

Related Code Sections


1004.8 Boilers, Water Heaters and Pressure Vessels, Burner Controls
Gas and oil modulating burners shall be provided with burner controls (oil and gas equivalent ratings) in accordance with Table 1004.8. TABLE ...
NYC Mechanical Code 2014 > 10 Boilers, Water Heaters and Pressure Vessels > 1004 Boilers > 1004.8 Burner Controls
1004.8 Boilers, Water Heaters and Pressure Vessels, Burner Controls
Gas and oil modulating burners shall be provided with burner controls (oil and gas equivalent ratings) in accordance with Table 1004.8 ...
NYC Mechanical Code 2008 > 10 Boilers, Water Heaters and Pressure Vessels > 1004 Boilers > 1004.8 Burner Controls
1006.8.1 Boilers, Water Heaters and Pressure Vessels, Remote Control (Shutdown)
A remote control shall be provided to stop the flow of oil and/or gas and combustion air to any burner or fuel burning internal combustion equipment ...
NYC Mechanical Code 2008 > 10 Boilers, Water Heaters and Pressure Vessels > 1006 Safety and Pressure Relief Valves and Controls > 1006.8 Electrical Requirements > 1006.8.1 Remote Control (Shutdown)
1006.8.1 Boilers, Water Heaters and Pressure Vessels, Remote Control (Shut Down)
A remote control shall be provided to stop the flow of oil and/or gas and combustion air to any burner or fuel-burning internal combustion equipment ...
NYC Mechanical Code 2014 > 10 Boilers, Water Heaters and Pressure Vessels > 1006 Safety and Pressure Relief Valves and Controls > 1006.8 Electrical Requirements > 1006.8.1 Remote Control (Shut Down)
1305.10 Fuel-Oil Piping and Storage, Devices to Control Flow to Oil-Burning Equipment
the maximum working pressure in that part of the system.   2. A remote control shall be provided to stop the flow of oil to any burner ...
NYC Mechanical Code 2008 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.10 Devices to Control Flow to Oil-Burning Equipment
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE