1907.7.4 Bundled Bars
Related Code Sections
1907.7.4 Concrete, Bundled Bars
The minimum specified concrete cover for bundled bars shall comply with ACI 318, Section 7.7.4 ...
R608.8.2.2 Wall Construction, Bundled Bars in Lintels
It is permitted to bundle two bars in contact with each other in lintels if all of the following are observed: Bars equal to or less than No. 6 ...
25.6 Reinforcement Details, Bundled Reinforcement
Groups of parallel reinforcing bars bundled in contact to act as a unit shall be limited to four in any one bundle ...
25.6 Reinforcement Details, Bundled Reinforcement
Groups of parallel reinforcing bars bundled in contact to act as a unit shall be limited to four in any one bundle ...
25.6.1.5 Reinforcement Details,
Development length for individual bars within a bundle, in tension or compression, shall be that of the individual bar, increased 20 percent ...