R310.3.2 Bulkhead Enclosures
JUMP TO FULL CODE CHAPTER
Bulkhead enclosures shall provide direct access from the basement. The bulkhead enclosure shall provide the minimum net clear opening equal to the door in the fully open position.
Bulkhead enclosures shall be designed for proper drainage by connecting to the building's foundation drainage system required by Section R405.1 or by an approved alternative method.
Exception: A drainage system for bulkhead enclosures is not required where the foundation is on well-drained soil or sand-gravel mixture soils in accordance with the United Soil Classification System, Group I Soils, as detailed in Table R405.1.
Related Code Sections
R310.3.2 Building Planning, Bulkhead Enclosures
Bulkhead enclosures shall provide direct access from the basement. The bulkhead enclosure shall provide the minimum net clear opening equal ...
Los Angeles Residential Code > 3 Building Planning > R310 Emergency Escape and Rescue Openings > R310.3 Emergency Escape and Rescue Doors > R310.3.2 Bulkhead Enclosures
R311.7.10.2 Building Planning, Bulkhead Enclosure Stairways
Stairways serving bulkhead enclosures, not part of the required building egress, providing access from the outside grade level to the basement shall ...
Los Angeles Residential Code > 3 Building Planning > R311 Means of Egress > R311.7 Stairways > R311.7.10 Special Stairways > R311.7.10.2 Bulkhead Enclosure Stairways
R311.7.10.2 Building Planning, Bulkhead Enclosure Stairways
Stairways serving bulkhead enclosures, not part of the required building egress, providing access from the outside grade level to the basement ...
Los Angeles Residential Code > 3 Building Planning > R311 Means of Egress > R311.7 Stairways > R311.7.10 Special Stairways > R311.7.10.2 Bulkhead Enclosure Stairways
1030.5 Means of Egress, Bars, Grilles, Covers and Screens
Bars, grilles, covers, screens or similar devices are permitted to be placed over emergency escape and rescue openings , bulkhead enclosures ...
Los Angeles Building Code > 10 Means of Egress > 1030 Emergency Escape and Rescue > 1030.5 Bars, Grilles, Covers and Screens
R310.4 Building Planning, Bars, Grilles, Covers and Screens
Bars, grilles, covers, screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosures ...
Los Angeles Residential Code > 3 Building Planning > R310 Emergency Escape and Rescue Openings > R310.4 Bars, Grilles, Covers and Screens