• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1302.1 Building System Risk Categories

California Plumbing Code 2019 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1302.0 Design Requirements > 1302.1 Building System Risk Categories
JUMP TO FULL CODE CHAPTER
Activities, systems, or equipment shall be designed to meet Category 1 through Category 4 requirements as detailed in this code. [NFPA 99:4.1]

1302.1.1 Risk Assessment

Categories shall be determined by following and documenting a defined risk assessment procedure. [NFPA 99:4.2.1]

1302.1.2 Documented Risk Assessment

A documented risk assessment shall not be required for Category 1. [NFPA 99:4.2.2]

Related Code Sections


1302.1 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Building System Risk Categories
Activities, systems, or equipment shall be designed to meet Category 1 through Category 4 requirements as detailed in this code. [NFPA 99:4.1 ...
California Plumbing Code 2019 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1302.0 Design Requirements > 1302.1 Building System Risk Categories
Section A102 Guidelines for the Seismic Retrofit of Existing Buildings, Scope
in Risk Category III or IV. Such buildings shall be strengthened to meet the requirements of the California Building Code for new buildings ...
California Existing Building Code 2016 > A Guidelines for the Seismic Retrofit of Existing Buildings > A102 Scope
8-706.1 Structural Regulations, Seismic Forces
jurisdiction. CEBC Section A102.2 shall not apply to Qualified Historical Buildings in Risk Category III buildings and other structures whose primary ...
California Historical Building Code 2019 > 8-7 Structural Regulations > 8-706 Lateral Load Regulations > 8-706.1 Seismic Forces
8-706.1 Structural Regulations, Seismic Forces
jurisdiction. CEBC Section A102.2 shall not apply to Qualified Historical Buildings in Risk Category III buildings and other structures whose primary ...
California Historical Building Code 2016 > 8-7 Structural Regulations > 8-706 Lateral Load Regulations > 8-706.1 Seismic Forces
1604.5 Structural Design, Risk Category
Each building and structure shall be assigned a risk category in accordance with Table 1604.5. Where a referenced standard specifies an occupancy ...
California Building Code 2016 (Vol 1 & 2) > 16 Structural Design > 1604 General Design Requirements > 1604.5 Risk Category
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE