// CODE SNIPPET
610.1.2 Building Prescriptive Compliance
JUMP TO FULL CODE CHAPTER
Buildings and surrounding property or building sites where there are multiple buildings on the building site, that are designed and constructed in accordance with Section 601.3.2, prescriptive compliance, shall be equipped with one or more renewable energy systems that have the capacity to provide not less than 2 percent of the total estimated annual energy use of the building, or collective buildings on the building site, with onsite renewable energy by calculation demonstrating that onsite renewable energy production has a rating of not less than 1.75 Btu/h (0.5 W) or not less than 0.50 watts per square foot of conditioned floor area, and using any single or combination of renewable energy generation systems meeting the requirements of Sections 610.2, 610.3, or 610.4.
Related Code Sections
610.1.2 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION, Building Prescriptive Compliance
in accordance with Section 601.3.2, prescriptive compliance, shall be equipped with one or more renewable energy systems that have the capacity to provide ...
Green Construction Code 2012 of Maryland > 6 ENERGY CONSERVATION, EFFICIENCY AND CO2e EMISSION REDUCTION > 610 Building Renewable Energy Systems > 610.1 Renewable Energy Systems Requirements > 610.1.2 Building Prescriptive Compliance
C502.2.3 [CE] Existing Buildings, Building Mechanical Systems
New mechanical systems and equipment that are part of the addition and serve the building heating, cooling and ventilation needs shall comply ...
Energy Conservation Code 2018 of Maryland > 5 [CE] Existing Buildings > C502 Additions > C502.2 Prescriptive Compliance > C502.2.3 Building Mechanical Systems
C502.2.3 [CE] Existing Buildings, Building Mechanical Systems
New mechanical systems and equipment that are part of the addition and serve the building heating, cooling and ventilation needs shall comply ...
Energy Conservation Code 2015 of Maryland > 5 [CE] Existing Buildings > C502 Additions > C502.2 Prescriptive Compliance > C502.2.3 Building Mechanical Systems
C502.2.1 [CE] Existing Buildings, Vertical Fenestration
New vertical fenestration area that results in a total building fenestration area less than or equal to that specified in Section C402.4.1 shall ...
Energy Conservation Code 2015 of Maryland > 5 [CE] Existing Buildings > C502 Additions > C502.2 Prescriptive Compliance > C502.2.1 Vertical Fenestration
C502.2.4 [CE] Existing Buildings, Service Water-Heating Systems
New service water-heating equipment, controls and service water heating piping shall comply with Section C404 ...
Energy Conservation Code 2018 of Maryland > 5 [CE] Existing Buildings > C502 Additions > C502.2 Prescriptive Compliance > C502.2.4 Service Water-Heating Systems