107.1.5 Building Framing Inspection
JUMP TO FULL CODE CHAPTER
Framing inspections shall be made after the roof (excluding permanent roof covering), wall ceiling, and floor framing is complete with appropriate blocking, bracing, and firestopping in place. The following items shall be in place and visible for inspection:
- Pipes;
- Chimneys and vents;
- Flashing for roofs and chimneys;
- Insulation baffles; and
- All lintels that are required to be bolted to the framing for support shall not be covered by any exterior or interior wall or ceiling finish material before approval. Work may continue without approval for lintels supported on masonry or concrete.
Related Code Sections
107.1.5 Administrative Code, Building Framing Inspection
Framing inspections
shall be made after the roof (excluding permanent roof covering),
wall ceiling, and floor framing is complete with
appropriate ...
North Carolina Administrative Code and Policies 2012 > 1 Administrative Code > 107 Inspections > 107.1 General > 107.1.5 Building Framing Inspection
107.1.5 Administrative Code, Building Framing Inspection
Framing inspections shall be made after the roof (excluding permanent roof covering), wall ceiling, and floor framing is complete with appropriate ...
North Carolina Administrative Code and Policies 2018 > 1 Administrative Code > 107 Inspections > 107.1 General > 107.1.5 Building Framing Inspection
Section 107 Administrative Code, Inspections
inspection;
Rough-in inspection;
Building framing inspection;
Insulation inspection;
Fire protection inspection; and
Final inspection ...
110.3 Scope and Administration, Required Inspections
The building official , upon notification, shall make the inspections set forth in Sections 110.3.1 through 110.3.10 ...
2018 North Carolina Building Code > 1 Scope and Administration > 110 Inspections > 110.3 Required Inspections