• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

703.1 Building Drain Pipe Near the Water Service

NYC Plumbing Code 2022 > 7 Sanitary Drainage > 703 Building Drain > 703.1 Building Drain Pipe Near the Water Service
JUMP TO FULL CODE CHAPTER
Where the building drain is installed underground and within 5 feet (1524 mm) of the water service, as provided for in Section 603.2, the building drain pipe shall conform to one of the standards for, cast-iron pipe, copper or copper-alloy tubing, or ductile iron listed in Table 702.3.

Related Code Sections


703.1 Sanitary Drainage, Building Drain Pipe Near the Water Service
Where the building drain is installed underground and within 5 feet (1524 mm) of the water service, as provided for in Section 603.2, the building ...
NYC Plumbing Code 2022 > 7 Sanitary Drainage > 703 Building Drain > 703.1 Building Drain Pipe Near the Water Service
Reference Standard 16 Plumbing and Gas Piping [PDF] (page 28)
horizontally, and shall be separated by compacted earth. The water service may be placed in the same trench with the building sewer and building drain ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 16 Plumbing and Gas Piping
Section 603 Water Supply and Distribution, Water Service
). Underground water service pipe and the building sewer or the building drain shall be separated by not less than 5 feet (1524 mm) of undisturbed ...
NYC Plumbing Code 2022 > 6 Water Supply and Distribution > 603 Water Service
Article 15 Plumbing and Gas Piping [PDF] (page 19)
president and the rules of the board. (14.9.7). §C26-1287.0 House Drains for Rear Buildings.-When a structure stands in the rear of another structure ...
NYC 1938 Code [PDF] > 15 Plumbing and Gas Piping
1301.9.9 Nonpotable Water Systems, Draining of Tanks
The tank drain pipe shall be indirectly connected to the appropriate building drainage system and discharge as required for overflow pipes and shall ...
NYC Plumbing Code 2022 > 13 Nonpotable Water Systems > 1301 General > 1301.9 Nonpotable Water Storage Tanks > 1301.9.9 Draining of Tanks
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING