Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

507.4.7 Building and Structural Contact

California Mechanical Code 2019 > 5 Exhaust Systems > 507.0 General Requirements > 507.4 Clearance > 507.4.7 Building and Structural Contact
JUMP TO FULL CODE CHAPTER
A duct shall be permitted to contact noncombustible floors, interior walls, and other noncombustible structures or supports, but it shall not be in contact for more than 50 percent of its surface area for each lineal foot of contact length. [NFPA 96:4.4.1]

507.4.7.1 Corrosion Protection

Where duct contact must exceed the requirements of Section 507.4.7, the duct shall be protected from corrosion. [NFPA 96:4.4.2]

507.4.7.2 Zero Clearance

Where the duct is listed for zero clearance to combustibles or otherwise protected with a material or product listed for the purpose of reducing clearance to zero, the duct shall be permitted to exceed the contact limits of Section 507.4.7 without additional corrosion protection. [NFPA 96:4.4.3]

Related Code Sections


507.3.7 Exhaust Systems, Building and Structural Contact
A duct shall be permitted to contact noncombustible floors, interior walls, and other noncombustible structures or supports, but it shall ...
California Mechanical Code 2016 > 5 Exhaust Systems > 507.0 General Requirements > 507.3 Clearance > 507.3.7 Building and Structural Contact
507.4.7 Exhaust Systems, Building and Structural Contact
A duct shall be permitted to contact noncombustible floors, interior walls, and other noncombustible structures or supports, but it shall ...
California Mechanical Code 2019 > 5 Exhaust Systems > 507.0 General Requirements > 507.4 Clearance > 507.4.7 Building and Structural Contact
1217.2 Hydronics, Radiant Under-Floor Heating
Floor surface temperatures shall not exceed the following temperatures: 85°F (29°C) in dwellings, buildings, or structures. 85°F (29°C ...
California Mechanical Code 2016 > 12 Hydronics > 1217.0 Radiant Heating and Cooling > 1217.2 Radiant Under-Floor Heating
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE