• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

605.11 Brass

Plumbing Code of the Texas Industrialized Housing and Buildings Program > 6 Water Supply and Distribution > 605 Materials, Joints and Connections > 605.11 Brass
JUMP TO FULL CODE CHAPTER
Joints between brass pipe and fittings shall comply with Sections 605.11.1 through 605.11.4.

605.11.1 Brazed Joints

All joint surfaces shall be cleaned. An approved flux shall be applied where required. The joint shall be brazed with a filler metal conforming to AWS A5.8.

605.11.2 Mechanical Joints

Mechanical joints shall be installed in accordance with the manufacturer's instructions.

605.11.3 Threaded Joints

Threads shall conform to ASME B1.20.1. Pipe-joint compound or tape shall be applied on the male threads only.

605.11.4 Welded Joints

All joint surfaces shall be cleaned. The joint shall be welded with an approved filler metal.

Related Code Sections


605.11 Water Supply and Distribution, Brass
Joints between brass pipe and fittings shall comply with Sections 605.11.1 through 605.11.4 ...
Plumbing Code of the Texas Industrialized Housing and Buildings Program > 6 Water Supply and Distribution > 605 Materials, Joints and Connections > 605.11 Brass
705.3 Sanitary Drainage, Brass
Joints between brass pipe or fittings shall comply with Sections 705.3.1 through 705.3.4 ...
Plumbing Code of the Texas Industrialized Housing and Buildings Program > 7 Sanitary Drainage > 705 Joints > 705.3 Brass
1203.5 Hydronic Piping, Brass Pipe
Joints between brass pipe or fittings shall be brazed, mechanical, threaded or welded joints conforming to Section 1203.3 ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 12 Hydronic Piping > 1203 Joints and Connections > 1203.5 Brass Pipe
1303.4 Fuel Oil Piping and Storage, Brass Pipe
Joints between brass pipe or fittings shall be brazed, mechanical, threaded or welded joints complying with Section 1303.3 ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 13 Fuel Oil Piping and Storage > 1303 Joints and Connections > 1303.4 Brass Pipe
1107.5.2 Refrigeration, Copper and Brass Pipe
Standard iron-pipe size, copper and red brass (not less than 80-percent copper) pipe shall conform to ASTM B 42 and ASTM B 43 ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 11 Refrigeration > 1107 Refrigerant Piping > 1107.5 Materials for Refrigerant Pipe and Tubing > 1107.5.2 Copper and Brass Pipe
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE