403.5 Bracing for Unreinforced Masonry Parapets Upon Reroofing
JUMP TO FULL CODE CHAPTER
Where the intended alteration requires a permit for reroofing and involves removal of roofing materials from more than 25 percent of the roof area of a building assigned to Seismic Design Category D, E or F that has parapets constructed of unreinforced masonry, the work shall include installation of parapet bracing to resist out-of-plane seismic forces, unless an evaluation demonstrates compliance of such items. For purposes of this section, design seismic forces need not be taken greater than 75 percent of those that would be required for the design of similar nonstructural components in new buildings of similar purpose and location.
Related Code Sections
403.5 Prescriptive Compliance Method, Bracing for Unreinforced Masonry Parapets Upon Reroofing
of a building assigned to Seismic Design Category D, E or F that has parapets constructed of unreinforced masonry, the work shall include installation ...
2015 Washington State Existing Building Code > 4 Prescriptive Compliance Method > 403 Alterations > 403.5 Bracing for Unreinforced Masonry Parapets Upon Reroofing
503.6 Prescriptive Compliance Method, Bracing for Unreinforced Masonry Parapets on Reroofing
of a building assigned to Seismic Design Category D, E or F that has parapets constructed of unreinforced masonry, the work shall include installation ...
2018 Washington State Existing Building Code > 5 Prescriptive Compliance Method > 503 Alterations > 503.6 Bracing for Unreinforced Masonry Parapets on Reroofing
706.3.1 Alterations — Level 1, Bracing for Unreinforced Masonry Bearing Wall Parapets
parapets constructed of unreinforced masonry, the work shall include installation of parapet bracing unless an evaluation demonstrates compliance ...
2018 Washington State Existing Building Code > 7 Alterations — Level 1 > 706 Structural > 706.3 Additional Requirements for Reroof Permits > 706.3.1 Bracing for Unreinforced Masonry Bearing Wall Parapets
707.3.1 Alterations - Level 1, Bracing for Unreinforced Masonry Bearing Wall Parapets
parapets constructed of unreinforced masonry, the work shall include installation of parapet bracing to resist the reduced International Building ...
2015 Washington State Existing Building Code > 7 Alterations - Level 1 > 707 Structural > 707.3 Additional Requirements for Reroof Permits > 707.3.1 Bracing for Unreinforced Masonry Bearing Wall Parapets
906.6 Alterations — Level 3, Bracing for Unreinforced Masonry Parapets
Parapets constructed of unreinforced masonry in buildings assigned to Seismic Design Category C, D, E or F shall have bracing installed as needed ...
2018 Washington State Existing Building Code > 9 Alterations — Level 3 > 906 Structural > 906.6 Bracing for Unreinforced Masonry Parapets