R602.10.9 Braced Wall Panel Support
JUMP TO FULL CODE CHAPTER
For SI: 1 inch = 25.4 mm.
Braced wall panel support shall be provided as follows:
- Cantilevered floor joists complying with Section R502.3.3 shall be permitted to support braced wall panels.
- Raised floor system post or pier foundations supporting braced wall panels shall be designed in accordance with accepted engineering practice.
- Masonry stem walls with a length of 48 inches (1219 mm) or less supporting braced wall panels shall be reinforced in accordance with Figure R602.10.9. Masonry stem walls with a length greater than 48 inches (1219 mm) supporting braced wall panels shall be constructed in accordance with Section R403.1 Methods ABW and PFH shall not be permitted to attach to masonry stem walls.
- Concrete stem walls with a length of 48 inches (1219 mm) or less, greater than 12 inches (305 mm) tall and less than 6 inches (152 mm) thick shall have reinforcement sized and located in accordance with Figure R602.10.9.

For SI: 1 inch = 25.4 mm.
MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
In Seismic Design Categories D0, D1 and D2, braced wall panel footings shall be as specified in Section R403.1.2.
Related Code Sections
R602.10.9 Wall Construction, Braced Wall Panel Support
Braced wall panel support shall be provided as follows:
Cantilevered floor joists complying with Section R502.3.3 shall be permitted to support ...
Residential Code 2018 of Kansas > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.9 Braced Wall Panel Support
R403.1.2 Foundations, Continuous footing in Seismic Design Categories D0, D1 and D2
in Seismic Design Category D 2 , in which all braced wall panels , interior and exterior, shall be supported on continuous foundations. Exception: Two ...
Residential Code 2018 of Kansas > 4 Foundations > R403 Footings > R403.1 General > R403.1.2 Continuous footing in Seismic Design Categories D0, D1 and D2
2308.4.9 Wood, Floor Framing Supporting Braced Wall Panels
Where braced wall panels are supported by cantilevered floors or are set back from the floor joist support, the floor framing shall comply ...
Building Code 2018 of Kansas > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing > 2308.4.9 Floor Framing Supporting Braced Wall Panels
R404.1.9.3 Foundations, Masonry Piers Supporting Braced Wall Panels
Masonry piers supporting braced wall panels shall be designed in accordance with accepted engineering practice ...
Residential Code 2018 of Kansas > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.9 Isolated Masonry Piers > R404.1.9.3 Masonry Piers Supporting Braced Wall Panels
R602.10.10.1 Wall Construction, Cripple wall bracing for Seismic Design Categories D0 and D1 and townhouses in Seismic Design Category C
In addition to the requirements in Section R602.10.10, the distance between adjacent edges of braced wall panel s for cripple walls along a braced ...
Residential Code 2018 of Kansas > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.10 Cripple Wall Bracing > R602.10.10.1 Cripple wall bracing for Seismic Design Categories D0 and D1 and townhouses in Seismic Design Category C