2308.3.4 Braced Wall Line Support
JUMP TO FULL CODE CHAPTER
Braced wall lines shall be supported by continuous foundations.
Exception:
For structures with a maximum plan dimension not over 50 feet (15 240 mm), continuous foundations are required at exterior walls only.
Related Code Sections
2308.3.4 Wood, Braced Wall Line Support
Braced wall lines shall be supported by continuous foundations.
Exception:
For structures with a maximum plan dimension not over 50 feet (15 240 ...
Building Code 2012 of Tennessee > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.3 Braced Wall Lines > 2308.3.4 Braced Wall Line Support
R602.10.7 Wall Construction, Braced Wall Panel Support
Braced wall panel support shall be provided as follows:
Cantilevered floor joists, supporting braced wall lines , shall comply with Section ...
Residential Code 2009 of Tennessee > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.7 Braced Wall Panel Support
R301.2.2.2.5 Building Planning, Irregular Buildings
a section of floor or roof is not laterally supported by shear walls or braced wall lines on all edges.
Exception: Portions of floors that do ...
Residential Code 2009 of Tennessee > 3 Building Planning > R301 Design Criteria > R301.2 Climatic and Geographic Design Criteria > R301.2.2 Seismic Provisions > R301.2.2.2 Seismic Design Category C > R301.2.2.2.5 Irregular Buildings
2308.12 Wood, Additional Requirements for Conventional Construction in Seismic Design Category D or E
headers having a span of 8 feet (2438 mm) or more.
Where a section of floor or roof is not laterally supported by braced wall lines on all ...
Building Code 2012 of Tennessee > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.12 Additional Requirements for Conventional Construction in Seismic Design Category D or E
R301.2.2.2 Building Planning, Seismic Design Category C
lines on all edges.
Exception: Portions of floors that do not support shear walls or braced wall panels above, or roofs, shall be permitted ...
Residential Code 2009 of Tennessee > 3 Building Planning > R301 Design Criteria > R301.2 Climatic and Geographic Design Criteria > R301.2.2 Seismic Provisions > R301.2.2.2 Seismic Design Category C