2308.3.2 Braced Wall Line Sill Plate Anchorage in Seismic Design Categories D and E
JUMP TO FULL CODE CHAPTER
Sill plates along braced wall lines in buildings assigned to Seismic Design Category D or E shall be anchored with anchor bolts with steel plate washers between the foundation sill plate and the nut, or approved anchor straps load-rated in accordance with Section 2304.10.3. Such washers shall be a minimum of 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. The hole in the plate washer is permitted to be diagonally slotted with a width of up to 3/16 inch (4.76 mm) larger than the bolt diameter and a slot length not to exceed 13/4 inches (44 mm), provided a standard cut washer is placed between the plate washer and the nut.
Related Code Sections
2308.3.2 Wood, Braced Wall Line Sill Plate Anchorage in Seismic Design Categories D and E
Sill plates along braced wall lines in buildings assigned to Seismic Design Category D or E shall be anchored with anchor bolts with steel plate ...
2018 North Carolina Building Code > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.3 Foundations and Footings > 2308.3.2 Braced Wall Line Sill Plate Anchorage in Seismic Design Categories D and E
R602.11 Wall Construction, Wall Anchorage
Braced wall line sills shall be anchored to concrete or masonry foundations in accordance with Sections R403.1.6 and R602.11.1 ...
2018 North Carolina Residential Code > 6 Wall Construction > R602 Wood Wall Framing > R602.11 Wall Anchorage
R602.11.2 Wall Construction, Stepped Foundations in Seismic Design Categories D0, D1 and D2
In all buildings located in Seismic Design Categories D 0 , D 1 or D 2 , where the height of a required braced wall line that extends from ...
2012 North Carolina Residential Code > 6 Wall Construction > R602 Wood Wall Framing > R602.11 Wall Anchorage > R602.11.2 Stepped Foundations in Seismic Design Categories D0, D1 and D2
2308.12.8 Wood, Sill Plate Anchorage
Sill plates shall be anchored with anchor bolts with steel plate washers between the foundation sill plate and the nut, or approved anchor straps ...
2012 North Carolina Building Code > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.12 Additional Requirements for Conventional Construction in Seismic Design Category D or E > 2308.12.8 Sill Plate Anchorage